Download Print this page
ENDA EPV242 Manual

ENDA EPV242 Manual

Programmable ac/dc voltmeter

Advertisement

Quick Links

Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you
don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material
damage or capital disadvantages.
ENDA EPV242 PROGRAMMABLE AC/DC VOLTMETER
ENDA EPV 4 2 2 Programmable
Thank you for choosing
77 x 35 mm sized
4 digits display
Selectable number of decimal point
Indicates between -999V and +9999V by using voltage transformer
Easy to use front panel keypad
Multi-function alarm output for lower and upper limits (NO + NC)
Multi-function alarm setpoints with alarm output (NO)
Communication feature over isolated RS485, using ModBus RTU protocol (Optional)
Measuring type can be selected as AC, DC or true RMS
CE Marked according to Europan Norms.
Order Code : EPV242 -
1 - Output
2 - Supply Voltage
230VAC...230V AC
R..........Relay
Blank....N/A
110VAC...110V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
Technical Specifications
ENVIRONMENTAL CONDITIONS
Ambient / torage emperature
S
T
Max. elative umidity
R
H
Rated ollution egree
P
D
Height
Do not use the device in locations subject to corrosive and flammable gases.
ELECTRICAL CHARACTERISTICS
Supply Voltage
Power onsumption
C
Wiring
Scale
Sensitivity
Accuracy
Input Range
Input Impedance
Frequency Range
EMC
Safety equirements
R
OUTPUTS
Alarm Output
Life Expectancy for Relay
HOUSING
Housing ype
T
Dimensions
Weight
Enclosure
M
aterial
While cleaning the device, solvents (thinner, gasoline, acid etc.) or
SURAN
Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
-
-
1
2
3
3 Isolated ModBus
-
RS ......
I
0 ... +50°C/-25 ... +70°C (with no icing)
80% Relative humidity for temperatures up to 31°C, decreasing linearly to 50% at 40°C.
According to EN 60529
;
Front Panel : IP6
Max. 2000m
230V AC +10
%
-20
%
or 24V AC %10, 50/60Hz or 9-30V DC / 7-24V AC 10
Max. 5VA
2.5mm² screw-terminal connections
utrr
AC and RMS
For
0...9999V,
utrr
DC
For
-999...9999V DC, for
u100
utrr
0,01V ( If,
or
is selected )
u500
0,1V (
If,
is selected and
u500
1V
(
If
is selected and
AC
±
%1
( Full scale )
DC
±
(
Full scale
%1
RMS
( Full scale )
±
%1
9
12
and
-500V...500V at
10
11
-
10
0V...
10
0V at
and
9
12
and
870kΩ
10
11
and
DC , 10Hz - 200Hz
(For square wave form 10Hz-70Hz)
EN 61326-1: 2013
EN 61010-1: 2010 (Pollution degree 2, overvoltage category II)
Relay: 250V AC, 8A (for resistive load), NO+NC
Mechanical 30.000.000 operation; 100.000 operation at 250V AC, 2A resistive load.
Suitable for flush-panel mounting. (According to DIN 43 700)
W77xH35xD 1mm
6
Approx.
2
50g (after packing)
Self extinguishing plastics.
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
AC/DC voltmeter.
Isolated
ModBus
(
Specify at order
)
5,
Rear Panel : IP20
±
u100
for
0........100V,
u100
-100...100V DC, for
higher than
-100V, lower from 100V for input values
lower than -100V
, higher from
( For square wave form
)
( For square wave form
u500
(Dielectric strength up to 1250 Vdc, above that the device will be damaged
utrr
u100
or
(Dielectric strength up to 250 Vdc, above that the device will be damaged).
corrosive materials
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
OUT
AC
DC
0. 0 00
ENDA
±
% (Optional)
u500
for
0...500V
u500
-500...+500V DC
)
100V
for input values
)
±
2% )
±
2% )
±
±
must not be used.
english
ACDC
V
SET
EPV242
).
1. / 4
EPV242-E-150419

Advertisement

loading
Need help?

Need help?

Do you have a question about the EPV242 and is the answer not in the manual?

Questions and answers

Summary of Contents for ENDA EPV242

  • Page 1 Read this document carefully before using this device. The guarantee will be expired by damaging of the device if you don't attend to the directions in the user manual. Also we don't accept any compensations for personal injury, material damage or capital disadvantages. ENDA EPV242 PROGRAMMABLE AC/DC VOLTMETER ENDA EPV 4 2 2 Programmable Thank you for choosing AC/DC voltmeter.
  • Page 2 DOUBLE INSULATION Connection Diagram ENDA EPV242 is intended for installation in control panels. Make sure that the device is used only for intended purpose. The electrical connections must be carried out by a qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power.
  • Page 3 EPV242 PROGRAMMING DIAGRAM ACDC Used for increasing the setpoint value and changing parameters. When held down for a few Increment seconds, configured numeric value increases faster. 0. 0 00 In "Runnig Mode", pressed for 3 seconds continuously, activates or deactivates keylock.
  • Page 4 ENDA EPV242 DIGITAL VOLTMETER MODBUS PROTOCOL ADDRESS MAP HOLDING REGISTERS FOR R EXTENSION DEVICES Holding Register Read/Write Data Content Parameter Status Data Addresses Permission Name Value Type Decimal 0000d 0tyP 0x0000 word Alarm output status Readable/Writable u. t . r . r...