Read this document carefully before using this device. The guarantee will be expired by
device damages if you don't attend to the directions in the user manual. Also we don't
accept any compensations for personal injury, material damage or capital disadvantages.
ENDA EPV 41 AC/DC VOLTMETER
2
A
Thank you for choosing ENDA EPV 41 AC/DC voltmeter.
* 77 x 3 mm sized.
5
* 3 digits display.
*
Values between -100V and 100 V can be indicated with one
decimal point.
* For maximum 50V AC/DC measurements;10 times the
sensitivity of the measurement values between -50V and +50V
with two decimal places to show.
* Easy to
configure with
* Multifunctional alarm output (NO+NC) for upper and lower
limits.
* With insulated rs485 ModBus protocol communication
feature.(optional)
* Measuring type can be selected AC, DC or True RMS.
Technical Specifications
ENVIRONMENTAL CONDITIONS
Ambient/stroge temperature
Max. Relative humidity
Rated pollution degree
Height
Do not use the device in locations subject to corrosive and flammable gases
ELECTRICAL CHARACTERISTICS
230V AC +10% -20%, 50/60Hz or 24V AC
Supply
Power consumption
Max. 5VA
Wiring
2.5mm² screw-terminal connections
Scale
AC and RMS
DC
Sensitivity
0,01V (If
0,1V (If
1V
Accuracy
AC
DC
RMS
Input Range
-500V...500V (
-50V
Input Impedance
870kΩ
Frequency Range
DC , 10Hz - 200Hz
EN 61326-1: 2006
EMC
Safety requirements
EN 61010-1: 20
OUTPUTS
Alarm output
Life expectancy for relay
HOUSING
Housing type
Dimensions
Weight
Enclosure material
While cleaning the device, solvents (thinner, benzine, acid etc.) or
SURAN
Industrieelektronik
Dettinger Str. 9 / D-72160 Horb a.N
2
front panel keypad.
1-Output
R ......Relay
None...No relay
0 ... +50°C/-25 ... 70°C
Relative humidity
80%
for temperatures
According to EN 60529
Max. 2000m
If
;
is selected,it is
C.InP 500
If
;
is selected, it is -500V DC....500V DC or If
C.InP 500
;50 is selected )
C.InP
CINP;500
is selected and higher than -100V or lower than 100V for input values)
(
If
is selected and lower than -100V or higher than 100V for input values
CINP 500
;
1%
(Full scale)
±
1%
(Full scale)
±
1%
(Full scale)
±
If
is selected,device breaks down at more than 1250 DC voltages.)
CINP 500
....50V
(
is selected,device breaks down at more than 125 DC voltages.)
If cInp 50
(For square wave form 10Hz-70Hz)
10
(Pollution degree 2, overvoltage category II)
Relay: 250V AC, 8A (for resistive load), NO+NC
Mechanical 30.000.000 ; Electrical 100.000 operation.
Suitable for flush-panel mounting. (According to DIN 43 700)
W
77
xH
35
xD7 mm
1
Approx. 350g (after packing)
Self extinguishing plastics.
Tel.: +49 (0)7451 / 625 617
Fax: +49 (0)7451 / 625 0650
Order Code : EPV241A-
2 Supply Voltage
-
230VAC...230V AC
110VAC...110V AC
24VAC.....24V AC
SM...........9-30V DC / 7-24V AC
up to 31°C decreasing linearly
Front panel : IP6
5
,
Rear panel :
.
±
10% , 50/60Hz or optional 9-30V DC / 7-24V AC 10% SMPS
0V...500V
or
If C.inP ;50 is selected,it is 0....50V
(For square wave form
±
(For square wave form
±
corrosive materials
E-mail : info@suran-elektronik.de
Internet : www.suran-elektronik.de
OUT
AC
DC
ACDC
ENDA
1
3-ModBus
RSI..... Insulated ModBus (optional)
to
50%
relative humidity
IP20
±
;
is selected,it is -50V DC....50V DC
C.InP 50
)
2%)
2%)
±
±
must not be used.
1. / 4
english
V
SET
SET
EPV 241A
-
-
3
2
at 40°C.
EPV 41 -E-10052019