Advertisement

Available languages

Available languages

Quick Links

Originalanhang
Original attachment
Annexe originale
Fass- und
Containerpumpe
F 430 S-41/38 TR
(Trockenaufstellung)
Seite 3 – 8
Drum and container
pump
F 430 S-41/38 TR
(for horizontal use)
Page 9 - 14
Pompes vide-fûts
F 430 S-41/38 TR
(pour utilisation
horizontale)
Page 15 - 20

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the F 430 S-41/38 TR and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Flux F 430 S-41/38 TR

  • Page 1 Originalanhang Original attachment Annexe originale Fass- und Containerpumpe F 430 S-41/38 TR (Trockenaufstellung) Seite 3 – 8 Drum and container pump F 430 S-41/38 TR (for horizontal use) Page 9 - 14 Pompes vide-fûts F 430 S-41/38 TR (pour utilisation...
  • Page 2 ! Lisez impérativement l'annexe « Pompes vide-fûts antidéflagrantes » avant de pomper des liquides inflammables ou d'utiliser le moteur et la pompe dans une zone à risque d’explosion. 2 / 24 F 430 S-41/38 TR...
  • Page 3: Bestimmungsgemäße Verwendung

    Vor dem Einsatz der Pumpe die Kupplung auf Leichtgängigkeit prüfen.  Überprüfen Sie durch Sichtkontrolle die Kupplung an der Pumpe und den Mitnehmer am Motor auf Verschleißspuren.  Bei Beschädigung Kupplung und Mitnehmer austauschen.  Verwenden Sie nur FLUX-Originalersatzteile. Anhang Fasspumpe F 430 S-41/38 TR 3 / 24...
  • Page 4 Beispiel Strömungswächter. Achtung!  Um das Leerlaufen an der Saugseite zu verhindern, verwenden Sie eine Füllstandsüberwachung des saugseitigen Behälters oder einen Strömungswächter.  Vermeiden Sie den Betrieb bei geschlossener Saugseite. 4 / 24 Anhang Fasspumpe F 430 S-41/38 TR …...
  • Page 5: Montage / Inbetriebnahme

    Container) schließen und den Motor abnehmen.  Prüfen Sie den Sitz des Motors. Pumpe nur in Betrieb nehmen, wenn die Überwurfmutter zwischen Pumpe und Motor von Hand fest angezogen ist. Anhang Fasspumpe F 430 S-41/38 TR … 5 / 24...
  • Page 6: Bedienung

    Herausspritzen der Flüssigkeiten zu verhindern.  Die Zapfpistole nach dem Abfüllvorgang abtropfen lassen. Im Auslaufrohr kann sich noch Flüssigkeit befinden, die dann unkontrolliert herausfließt.  Verschüttete Flüssigkeit am Boden entfernen und umweltgerecht entsorgen. 6 / 24 Anhang Fasspumpe F 430 S-41/38 TR …...
  • Page 7 Keinesfalls darf die Pumpe zusammen mit dem Behälter transportiert werden. > Der Netzstecker muss gezogen und das Netzkabel aufgerollt sein. > Pumpe, Schlauch und Armaturen vor dem Transport entleeren. Die Armaturen zum Entleeren ganz öffnen. Anhang Fasspumpe F 430 S-41/38 TR … 7 / 24...
  • Page 8: Wartung / Reparatur

    Pumpe, Schlauch, und Armaturen vor der Demontage entleeren. > Umweltschädliche Substanzen und Flüssigkeiten in geeigneten Behältern auffangen und umweltgerecht entsorgen. > Schrott, nicht reparable oder nicht wiederverwendbare Teile umweltgerecht entsorgen. 8 / 24 Anhang Fasspumpe F 430 S-41/38 TR …...
  • Page 9: Intended Use

    FEM 4070, F 457, F 457 EL, F 458, F 458 EL, F 458-1 in hazardous areas: F 460 Ex, F 460 Ex EL, F 460-1 Ex, FBM 4000 Ex Compressed-air motors F 416 Ex, F 416-1 Ex, F 416-2 Ex Attachment drum pump F 430 S-41/38 TR … 9 / 24...
  • Page 10 Working in hazardous areas The marking of the pump F 430 S-41/38 TR is II 2 G Ex h IIB T4 Gb X. Achtung!  The liquid temperature must not exceed 40°C.  The pump is designed for operation at ambient temperatures from -20°C to + 40°C..
  • Page 11: Operation

     The operator must be instructed on proper use before operating the pump.  Use the pump only for its intended purpose.  Do not leave the pump unattended. Attachment drum pump F 430 S-41/38 TR 11 / 24...
  • Page 12 On the FEM 4070, F457 EL, F458 EL and F460 Ex EL motors, use the control knob to set the desired speed (regulation of the delivery rate).  Do not leave the pump unattended. 12 / 24 Attachment drum pump F 430 S-41/38 TR...
  • Page 13 Rinse the pump with a suitable cleaning agent. The pump and hose must be resistant to the cleaning agent..  Do not use flammable liquids.  Observe the safety instructions. Attachment drum pump F 430 S-41/38 TR 13 / 24...
  • Page 14: Maintenance & Repair

    Collect environmentally harmful substances and liquids in appropriate containers and dispose of them in an environmentally sound manner. > Dispose of scrap material and parts that cannot be repaired or reused in an environ- mentally sound manner. 14 / 24 Attachment drum pump F 430 S-41/38 TR...
  • Page 15: Utilisation Conforme

    Inspecter visuellement l'accouplement de la pompe et le conducteur au moteur l'entraînement pour détecter tout signe d'usure.  En cas d’endommagement, remplacer l’accouplement et le conduc- teur.  N'utiliser que des pièces détachées d'origine FLUX. Annexe pompes vide-fûts F 430 S-41/38 TR … 15 / 24...
  • Page 16 Moteurs pneumatiques F 416 Ex, F 416-1 Ex, F 416-2 Ex Travailler en zones explosives Le marquage de la pompe F 430 S-41/38 TR est II 2 G Ex h IIB T4 Gb X. Attention !  La température du liquide ne doit pas dépasser 40°C.
  • Page 17: Montage / Mise En Service

    IBC) et retirer le moteur.  Vérifier la fixation du moteur. Ne mettre la pompe en service que si l'écrou-raccord entre la pompe et le moteur est bien serré à la main. Annexe pompes vide-fûts F 430 S-41/38 TR 17 / 24...
  • Page 18: Opération

    Une fois le transvasement terminé, vidanger le flexible et le pistolet, afin d’éviter tout écoulement de produit de manière incontrôlée.  Enlever tout liquide qui a été renversé sur le sol et l'éliminer dans le respect de l'environnement. 18 / 24 Annexe pompes vide-fûts F 430 S-41/38 TR...
  • Page 19 La fiche d'alimentation doit être débranchée et le câble d'alimentation enroulé. > Vider la pompe, le tuyau et les armatures avant le transport. Ouvrir les robinets complètement pour les vider. Annexe pompes vide-fûts F 430 S-41/38 TR 19 / 24...
  • Page 20: Entretien Et Réparation

    Recueillir les substances et liquides nuisibles à l'environnement dans des contenants appropriés et les éliminer en respectant l'environnement. > Eliminer les ferrailles et les pièces non réparables ou devenues inutilisables en respectant l'environnement. 20 / 24 Annexe pompes vide-fûts F 430 S-41/38 TR...
  • Page 21 EU Konformitätserklärung EU Declaration of Conformity Déclaration de Conformité UE F 430 S-41/38 TR 21 / 24...
  • Page 22 22 / 24 F 430 S-41/38 TR...
  • Page 23 F 430 S-41/38 TR 23 / 24...

Table of Contents