Code
Type
Mode
R
Right Adjust
ALL
v
ALL
v
v
Remote Abort
COMM
1
Causes
• Pressed a data key after the right
adjust field was filled.
• Entered a data key after all charac·
ters were verified.
• A mismatch occurred on a fill char·
acter for a right adjust field.
• Pressed - (dash) or RIGHT ADJ at
the start of a field that isn't all fill
characters or contains the wrong
type of fill characters. (The error
occurs when the first non-fill char·
acter is encountered.)
• Pressed RIGHT ADJ or - (dash) be·
fore all characters in the field were
verified.
• The remote location is prematurely
ending the job.
1
COMM identifies errors that occur during communications, see
Communications.
What You Do
Reset, press RIGHT ADJ or FIELD
BKSP, and re-enter the field.
Reset and press RIGHT ADJ.
Reset and correct the program.
Reset and if the dash and RIGHT ADJ
are correct, press FIELD COR and
change the field.
Reset and correct the field.
When the remote location is ready,
re-establish the connection.
242