KCT2-6ST-V
KC-LED-96-1T-24VDC
3.5 Decimal point
The decimal point defines the
resolution of the pro gram med
time unit.
0
0.0 1/10 (0,1)
0.00 1/100 (0,01)
0.000 1/1000 (0,001)
3.6 SET/RESET mode
manual reset via the red SET/
RESET key and electrical reset
via the SET/RESET input
no reset (red SET/RESET key
and SET/RESET input locked)
only electrical reset via the
SET/RESET input
only manual reset via the red
SET/RESET key
3.7 SET value
The device will be set to the
set point by pressing the red
SET/RESET key or activating
the SET/RESET input.
SET value 0 ...999 999 or
99.59.59 (number of decimal
places depends on the decimal
point option)
3.8 End of programming
The programming routine is re-
peated once more. The values
set until now can be checked
and modified.
The programming routine wil
be left and all values set will be
stored as new parameters.
Afterwards the device is ready
for operation.
1

5. Technical data

Supply voltage
AC power supply:
DC power supply:
Display:
Data retention:
Polarity of the inputs:
Input resistance:
Count frequency:
AC power supply:
Input level:
typ. Low Level:
typ. High Level:
Fmax:
CntDir
UpDown
Up.Up
Quad1
Quad2
Quad4
DC power supply:
Input level:
typ. Low Level:
typ. High Level:
Fmax:
CntDir
UpDown
Up.Up
Quad1
Quad2
Quad4
100 ... 240 VAC/max. 8 VA
Tolerance ±10%, 50/60 Hz
ext. fuse protection: T 0.1 A
10 ... 30 V DC/max. 50 mA
with inverse-polarity
protection
SELV, CLASS II (Limited
Power Source)
ext. fuse protection: T 0.1 A
6 digits, red 7 segment
LED display, height 14 mm
EEPROM
Programmable, npn or pnp
for all inputs
appr. 5 kOhm
100 ... 240 VAC ±10%
Standard
2,5 V
22,0 V
kHz
60
25
25
25
25
15
24
12 V DC
Standard
2,5
2,0 V
22,0
10 V
kHz
kHz
60
20
25
15
25
15
25
15
25
15
15
15
ENG / 9