Graco 236-463 Instructions-Parts List Manual page 11

Pumps with severe-duty rod and cylinder
Table of Contents

Advertisement

Flush the Pump Before First Use
The pump is tested with lightweight oil, which is left in
to protect the pump parts. If the fluid you are using
may be contaminated by the oil, flush it out with a
compatible solvent. See Flushing on page 12.
Starting and Adjusting the Pump
1. See Fig. 2. Connect the suction kit (T) to the
pump's fluid inlet. Place the tube into the fluid
supply.
2. Close the air regulator (F).
3. Open the pump's bleed-type master air valve (E).
4. Hold a metal part of the gun (S) firmly to the side
of a grounded metal pail and hold the trigger open.
5. Slowly open the regulator until the pump starts.
6. Cycle the pump slowly until all air is pushed out
and the pump and hoses are fully primed.
7. Release the gun trigger and lock the trigger safety.
The pump should stall against pressure.
8. If the pump fails to prime properly, open the drain
valve (M). Use the drain valve as a priming valve
until the fluid flows from the valve. Close the valve.
NOTE: When changing fluid containers with the hose
and gun already primed, open the drain valve (M) to
help prime the pump and vent air before it enters the
hose. Close the drain valve when all air is eliminated.
Operation/Maintenance
CAUTION
Do not allow the pump to run dry. It will quickly
accelerate to a high speed, causing damage. If your
pump is running too fast, stop it immediately and
check the fluid supply. If the container is empty and
air has been pumped into the lines, refill the con-
tainer and prime the pump and the lines, or flush and
leave it filled with a compatible solvent. Eliminate all
air from the fluid system.
9. With the pump and lines primed, and with ade-
quate air pressure and volume supplied, the pump
will start and stop as you open and close the gun.
In a circulating system, the pump will speed up or
slow down on demand, until the air supply is shut
off.
WARNING
COMPONENT RUPTURE HAZARD
To reduce the risk of overpressurizing
your system, which could cause compo-
nent rupture and serious injury, never
exceed the specified Maximum Incoming Air Pres -
sure to the pump (see Technical Data, page 25).
10. Use the air regulator (F) to control pump speed
and fluid pressure. Always use the lowest air
pressure necessary to get the desired results.
Higher pressures cause premature tip and pump
wear.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dura-flo 600237-369

Table of Contents