Technical Specifications
BURNER TYPE
Output
Fuel
Category
Gas rate- Natural gas
Gas pressure
Power supply
Total power consumption
Electric motor
Protection
Operation
Gas train 50
Gas train 65
Gas train 80
Gas train 100
Operating temperature
Storage Temperature
Working service
BURNER TYPE
Output
Fuel
Category
Gas rate- Natural gas
Gas pressure
Power supply
Total power consumption
Electric motor
Protection
Operation
Gas train 50
Gas train 65
Gas train 80
Gas train 100
Operating temperature
Storage Temperature
Working service
Note1:
All gas flow rates are referred to Stm
(net calorific value H
Note2:
Maximum gas pressure = 360 mbar (with Dungs MBDLE)
Minimum gas pressure = see gas curves.
Note3:
Burners are suitable only for indoor operation with a maximum relative humidity of 80 %
Country and usefulness gas categories
GAS
CATEGORY
I
AT
ES GR SE
2H
I
LU
PL
2E
I
BE
-
2E( R ) B
(*) I
NL
-
2EK
I
DE
-
2ELL
I
FR
-
2Er
(*) Only for I
: the appliance was configured for the appliance category K (I2K) and is suitable for the use of G and G+ distribution gases according to the specifications as
2EK
included in the NTA 8837:2012 Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0 °C, upper value) or 41.23 – 42.98 (dry, 15 °C, upper value). This appliance can
moreover be converted and/or be calibrated for the appliance category E (I2E). This therefore implies that the appliance "is suitable for G+ gas and H gas or is demonstrably
suitable for G+ gas and can demonstrably be made suitable for H gas" within the meaning of the "Dutch Decree of 10 May 2016 regarding amendment of the Dutch Gas
Appliances Decree and the Dutch Commodities (Administrative Fines) Act in connection with the changing composition of gas in the Netherlands as well as technical
amendment of some other decrees.
min. - max. kW
3
min.- max. (Stm
/h)
mbar
kW
kW
Valves size / Gas connection
Valves size / Gas connection
Valves size / Gas connection
Valves size / Gas connection
°C
°C
min. - max. kW
3
min.- max. (Stm
/h)
mbar
kW
kW
Valves size / Gas connection
Valves size / Gas connection
Valves size / Gas connection
Valves size / Gas connection
°C
°C
3
/ h (1.013 mbar absolute pressure, 15 °C temperature) and are valid for G20 gas
3
= 34,02 MJ / Stm
i
= 500 mbar (with Siemens VGD or Dungs MultiBloc MBE)
FI
IE
HU
IS
NO CZ DK GB
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
RX92R-FGR M-..
320 - 1870
34 - 198
8
7.5
RX512-FGR M-..
RX515-FGR M-..
1280 - 3600
1065 - 4160
135 - 381
230V 3~ / 400V 3N ~ 50Hz
11.5
11
50 / Rp2
65 / DN65
80 / DN80
100 / DN100
100 / DN100
); for L.P.G. (net calorific value H
COUNTRY
IT
PT CY EE LV
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
7
PART I: SPECIFICATIONS
RX92-FGR M-..
680 - 2504
Natural gas
M -
see next paragraph
(
)
72 - 265
see Note 2
(
)
230V 3~ / 400V 3N ~ 50Hz
8
7.5
IP40
MD - Fully modulating
50 / Rp 2
65 / DN65
80 / DN80
100 / DN100
-10 ÷ +50
-20 ÷ +60
Continuous
RX520-FGR M-..
1600 - 4816
Natural gas
M -
see next paragraph
(
)
113 - 440
169 - 510
see Note 2
(
)
15.5
15.5
15
15
IP40
MD - Fully modulating
50 / Rp2
50 / Rp2
65 / DN65
65 / DN65
80 / DN80
80 / DN80
100 / DN100
-10 ÷ +50
-20 ÷ +60
Continuous
3
= 93,5 MJ / Stm
)
i
SI
MT SK BG LT RO TR CH
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
RX512R-FGR M-..
680 - 2800
72 - 296
11.5
11
RX525-FGR M-...
1550 - 6320
164 - 669
400V 3N ~ 50Hz
19
18.5
-
65 / DN65
80 / DN80
100 / DN100
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Need help?