Only use the device in private households.
Intended use:
For notes on functional principle, see chapter Operation.
Danger of death and risk of damage when pumping explosive, flammable or unsuitable substances!
Flammable or explosive substances may ignite or explode.
Unsuitable substances can damage the pump.
Do not pump explosive, flammable or corrosive liquids or gases (e.g. fuels, petroleum, nitro thinner) and do not pump fats, oils, salt water or waste water from sanitary facilities or water that has a lower flowing ability than clean water.
Permissible feed fluids:
ATTENTION
Risk of damage due to frost!
Operation during frost may damage the device.
An incompletely emptied device can be damaged by frost.
Do not operate the device during frost.
Protect the device from frost.
ATTENTION
Risk of damage during continuous operation!
The device is not suitable for continuous operation.
Do not operate the device continuously for long periods (e.g. continuous circulation operation in ponds) or as a stationary installation (e.g. as a water lifting system, fountain pump).
Note
The manufacturer accepts no liability for possible damage caused by improper use or incorrect operation.
ATTENTION
Only use original accessories and original spare parts. They ensure that the appliance will run fault-free and safely.
Information on accessories and spare parts can be found at www.kaercher.com.
The scope of delivery for the appliance is shown on the packaging. Check the contents for completeness when unpacking. If any accessories are missing or in the event of any shipping damage, please notify your dealer.
Risk of electric shock and risk of injury!
The device contains electrical and mechanical components.
Always disconnect the device from the power supply before assembling, disassembling or cleaning.
Note
The shorter the hose length and larger the hose diameter, the higher the delivery rate.
To avoid clogging the pump, use a pre-filter for hose diameters smaller than 1 ¼'.
The pump connection is equipped with a plug system (Quick-Connect).
The Connection nozzle with G 1 ½ pump connecting piece is supplied unmounted with the device.
Note
Hoses with a diameter of 1', 1 ¼' and 1 ½' can be connected to the pump connecting piece G 1 ½.
A sufficiently large hose diameter must be selected and the pump connecting piece must be shortened according to the grooves so that the required particle size can be used. A large hose diameter is also recommended for smaller particle sizes to allow a high flow volume.
Connecting the hose to the pump:
Erecting/immersing the pump:
Danger of death from electric shock.
Danger of death from electric shock if live parts are touched.
During operation, do not touch the rope attached to the carrying handle or any objects that are in contact with the pumped liquid (e.g. pipelines protruding into the pumped liquid, railings) and do not reach into the pumped liquid.
Note
In automatic mode, the level sensor controls the pumping process automatically. The pump switches on when the level sensor makes contact with the rising pumped liquid.
The pump switches off when the level sensor loses contact with the falling pumped liquid and an after-running time of 15 s has expired.
Switching on:
Minimum fluid level required to enable the pump to suck independently (= minimum switch-on point):
Highest adjustable switching height of the level sensor:
Minimum residual fluid height/max. suction depth:
Note
It is recommended to use the pre-filter.
Note
Make sure that the pump stands level. Otherwise the level sensor may not lose contact with the fluid and the pump can run dry.
Application area | SP 17.000 Flat Level Sensor | SP 22.000 Dirt Level Sensor |
Shafts with a diameter < approx. 1 m (e.g. drainage) | Level sensor in uppermost position | Level sensor in uppermost position |
We recommended using the pre-filter | Pre-filter flap closed (protection against soiling) | |
Swimming pools, ponds (only for SP 22000 Dirt Level Sensor) | Level sensor in lowest position | Level sensor in lowest position |
Starting pumping with the pre-filter or folded-out feet | Pre-filter flap closed (protection against soiling) | |
Continuing pumping without the pre-filter and folded-in feet (reaches a residual fluid height of 1 mm) Note Perform in manual mode. Monitor the switch-off/ shallow suction. |
Note
In manual mode, the pump stays switched on.
ATTENTION
Risk of damage from dry running!
Dry running leads to increased wear on the pump.
Do not leave the pump unattended in manual operation. In case of dry running, immediately pull the mains plug out of the socket.
It is recommended to use manual mode to reach the min. residual fluid height of 1 mm.
A check valve is installed in the SP 17.000 Flat Level Sensor. This prevents residual fluid in the hose from flowing back after the pumping process finishes.
Risk of electric shock and risk of injury!
The device contains electrical and mechanical components.
Cleaning and user maintenance may not be carried out by children.
ATTENTION
Risk of damage!
Risk of damage due to dried soiling or additives.
Rinse and clean the device immediately after each use.
The device is maintenance-free.
Manual transport
Risk of injury from tripping!
There is a risk of injury from tripping on loose cables and hoses.
Be careful of cables and hoses when moving the device.
ATTENTION
Risk of damage due to frost!
An incompletely emptied device can be damaged by frost.
Completely empty the device and accessories before storing them.
Protect the device from frost.
Store the device in a frost-free place and not outdoors.
Risk of injury and damage!
The device may tip over on sloping surfaces.
Be aware of the weight of the device during storage.
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
Fault | Cause | Rectification |
The pump is running, but not delivering | Air is in the pump. |
|
The suction area is clogged. |
| |
Water level below the minimum liquid level. |
| |
The pump does not start up, or stops suddenly during operation | The power supply is disconnected. |
|
The thermal protection switch has switched off the pump because of overheating. |
| |
Dirt particles block the suction area. |
| |
The level sensor stops the pump. |
The pump stops 15 s after the level sensor no longer has contact with the water. | |
The level sensor does not react because it is soiled. |
| |
The pumping capacity decreases | The suction area is clogged. |
|
The delivery rate is too low | The maximum delivery head is exceeded. The hose diameter and the hose length have been selected incorrectly. |
|
Quick-Connect cannot be opened or closed | The push-fit system is dirty. |
|
The pump runs although the level sensor has no contact with the water | The level sensor does not react because it is soiled. |
|
The switch is set to Manual mode (MAN). |
| |
Extended after-running time | The level sensor is dirty. |
|
SP 17.000 Flat Level Sensor | SP 22.000 Dirt Level Sensor | ||
Device performance data | |||
Mains voltage | V | 230-240 | 230-240 |
Power frequency | Hz | 50 | 50 |
Nominal power | W | 550 | 750 |
Maximum flow rate | l/h | 17,000 | 22,000 |
Pressure (max.) | MPa (bar) | 0.09 (0.9) | 0.08 (0.8) |
Delivery height (max.) | m | 9 | 8 |
Immersion depth (max.) | m | 7 | 7 |
Perm. temp. feed fluid | °C | 5...35 | 5...35 |
Particle size (max.) of permissible feed fluids | mm | 5 | 30 |
Minimum fluid level (manual mode) | mm | 7 | 50 |
Residual fluid height | mm | 1 | 35 |
Weight (without accessories) | kg | 6 | 6.7 |
Subject to technical modifications.
The flow rate is further increased: