Installation Instructions
Original Instructions
Industrial Computers and Thin Clients for Hazardous Locations, Series J
Catalog Numbers 6181X-000NWNNDNB-3xNNNNxG-xxx(x), 6181X-000NWNNDNB-3xxxxxxG-xxx(x), 6181X-121PPMXDNB-3xNNNNxG-xxx(x), and
6181X-121PPMXDNB-3xxxxxxG-xxx(x)
Topic
Read this document and the documents that are listed in the
before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition
to requirements of all applicable codes, laws, and standards.
Activities including installation, adjustments, putting into service, use, assembly, disassembly, and maintenance are required to be carried out by suitably
trained personnel in accordance.
Installation Precautions
Read and follow these precautions before you install your industrial computer or thin client for hazardous locations.
Environment and Enclosure Information
ATTENTION: This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage Category II applications (as defined in
IEC 60664-1), at altitudes up to 2000 m (6561 ft) without derating.
This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 32 and ABNT NBR IEC/CISPR 32. Without appropriate
precautions, there can be potential difficulties with electromagnetic compatibility in other environments due to conducted and radiated disturbance.
The equipment must be panel mounted or open-type, and installed in a tool-only accessible enclosure that is suitable for the environment.
All 6181X-121 integrated display industrial computers and 6181X-121 integrated display thin clients are shipped with a gasketed bezel to meet specified
ratings when mounted in a panel or enclosure with an equivalent rating. For more information about these ratings,
see
Hazardous Location Information on page
In addition to this publication, see the following:
• Publication 1770-4.1, Industrial Automation Wiring and Grounding Guidelines, for more installation requirements
• ABNT NBR IEC 60529, NEMA 250, UL 50, and IEC 60529, as applicable to your region, for explanations of the degrees of protection that are provided by
enclosures
European Union Directive/United Kingdom Regulations
These industrial computers and thin clients meet the European Union Directive requirements when installed within the European Union or EEA regions and has the CE
marking. Additionally, these industrial computers and thin clients meet the United Kingdom regulation requirements when installed within the United Kingdom and has the
UKCA marking. Copies of the declarations of conformity are available at rok.auto/certifications.
ATTENTION: To comply with EN 55024 and EN 55032, the following applies to cable usage:
• USB cables must be less than 3 m (9.84 ft) long
• All I/O cables, except for Ethernet cables, must be used indoors
• All I/O cables, except for Ethernet cables, cannot exit the building at any point and cannot directly connect to cables outside the building
To comply with EN 55024 and EN 55032, use the following for cable types:
Cable Type
Required Attribute
LAN
Shielded or unshielded
USB
2.
Cable Type
Serial RS-232
Shielded
Page
1
2
3
5
5
8
9
10
14
Additional Resources
section about installation, configuration, and operation of this equipment
Required Attribute
Shielded
DVI
Shielded
Cable Type
Required Attribute
DisplayPort
Shielded
DC Power
Unshielded