Internal circuit Diagram
■
Terminal layout
Although the positive and negative terminals are connected internally, connect these terminals
externally as well.
2.3.5 32-point Source-type Transistor Output Unit
■
Description
Items
Insulation system
Output type
Rated load voltage
Allowable load voltage range
Max. load current
WUME-FP7DIO-05
AFP7Y32P
Optical coupler
Open collector
5 to 24 V DC
4.75 to 26.4 V DC
0.3 A (26.4 to 20.4 V DC) and 30 mA (4.75 V DC)
2.3 Output Unit Specifications