Band-it GRSM17 Owner's Manual And Operating Instructions page 6

Pneumatic center punch tool
Table of Contents

Advertisement

Installing
Clamps
Installing BAND-IT Center Punch Clamps:
1)
Choose correct material type and diameter clamp to best satisfy the needs of the application.
2)
Installation of two BAND-IT Center Punch Clamps per hose end is suggested. Place clamps over hose, then
install fitting. Note the location of the fitting's hose barbs in order to locate clamps between barbs for maximum
fitting retention. The buckles of each clamp should be located opposite of each other to increase resistance to
leak paths.
3)
Insert the clamp tail fully into the nose of the tool with the buckle on top. Position the clamp in the desired
location on hose.
4)
Small diameter hose assemblies (less than approximately 2") will receive a considerable impact during the lock
and clamp tail cut-off process. For stiff hoses, it will help to lessen the impact by holding these small hose
assemblies with only one hand on the hose end of the assembly (do not hold the end of the assembly with the
fitting). This will soften the jolt and allow the assembly to swing down to absorb the impact. For flat or thin-wall
hose, inserting an object that is soft and safe to hold into the end of the fitting for additional support may help.
Large diameter hose assemblies should be held securely with both hands.
Keep hands away from clamp being applied!
5)
Depress the toe end of the foot pedal control to tension clamp, keep the toe end down until the clamp has been
fully tensioned, locked and cut-off is complete.
6)
If the cylinder reaches the end of its stroke during tension, the cutoff cylinder will be disabled and the end-of-
stroke indicator will turn red. Pull firmly on the clamp while reversing the cylinder. Remove the clamp. Before
stroke indicator will turn red. Pull firmly on the clamp while reversing the cylinder. Remove the clamp. Before
regripping, cut off any tail greater than 4 inches. Start the tension cycle over at step 3.
7)
Depress the heel end of the foot control and retrieve the clamp tail from the tool head.
Clamp tail inserted into blade
assembly
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street Denver, CO 80216-3070 USA
P: 1-800-525-0758 F: 1-800-624-3925
Guard/tail depressor provides downward
pressure on scrap clamp tail.
www.BAND-IT-IDEX.com
6
GRSM17
Pneumatic
Center Punch
Tool
Clamp tail in normal return
position. Pull tail from tool.
Document# P47050 Rev. -
© Copyright
BAND-IT-IDEX, Inc. 2008
All rights reserved