Promix 2Ks Installation - Graco 15V823 Instructions And Parts

Gun air shutoff kit
Table of Contents

Advertisement

ProMix 2KS Installation

Install Solenoid
1. Turn off EasyKey™/Control Box power, and shut off
power at main circuit breaker (See your Installation
and Repair-Parts manual in Related Manuals,
page 2.)
2. Remove Fluid Panel cover to access the solenoids.
3. Remove two sealing screws (SS), and install sole-
noid valve (3). Tighten screws to secure.
(See F
. 2-1)
IG
2-1
G1
3
2-3
1
F
. 2: Solenoid Connections at Fluid Panel, ProMix 2KS
IG
310745J
SS
G2
4, G1
4, G2
4. Connect solenoid wires to terminals as shown in
F
. 2-2.
IG
5. Remove air manifold plug from row B (marked on
manifold, bottom row) and install tube fitting (4, G1).
(See F
. 2-3).
IG
1
In a two-gun ProMix 2KS system, install the sec-
ond solenoid (G2) as shown.
G1
2-2
Red
Black
Red
G
G
Installation
G2
1
Black
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

23492815v829

Table of Contents