11.
Key Input check
I
Address 01
I
Page 2
I
Category 3F
Bit
Key Switch
Condition of Switch
0
Date (
+)
(CF block S924)
Time (CF block S925)
2
Cassette eject (DD-55 S451)
"1"=0FF
3
Video power supply (Power switch unit S900)
"O"=ON
4
Auto lock (CF block S927)
5
Start/Stop (SW-222 S904)
6
CC DOWN (Mechanism section)
7
Camera power supply (Power switch unit S900)
Using method:
Order
Page
Address
Data
Procedure
1
2
00
3F
Specification of category
3F
2
2
01
12.
Key Input check (AID Port)
I
Page 2
I
Category 01
~
OOto 10
s
a
The on/off of each key switch can be discriminated by
differentiating the bit values of the display data.
I
Address 16
to
1A
11 to 4C
4Dto 7E
7Fto 81
B2to E7
Foward
Edit search (
+)
Edit search (-)
16
STOP
(ADO: IC902
@ I
(CF block S9011
(CF block S902)
(CF block S904)
(CF block S905)
17
Pause
Rewind
Playback
Menu
IAD1: IC902
®!I
(CF block S9061
(CF block S907)
(CF block S908)
(CF block S909)
18
Slow
Set
Item
IAD2: IC902
®
I
(CF block S9101
(CF block S911)
(CF block S912)
19
Program AE
Focus
(AD3: IC902 1@1
(CF block S9131
(CF block S9151
1A
Reset
(AD4: IC902
(@
I
(CF block S9181
Using method:
Order
Page
Address
Data
Procedure
2
00
01
2
2
16to1A
Specification of category 00
The key pressed can be discriminated by the display
data of each address.
-214-
Fader
(CF block S9171
Steady shot
(CF block S922)
ESto FF
No key input
No Key input
No key input
No key input
No key input
13.
Wireless
check
remote commander reception contents
Page 2
I
Category 01
I
Address 11
Display Data
Pressed Key of Wireless Remote
Commander
FF
Non
9A
TELE
98
WIDE
99
Start/Stop
18
REW
1C
FWD
18
Stop
1A
Playback
19
Pause
5A
Data screen
23
Slow
Using method:
Order
Page
Address
Data
Procedure
2
00
01
Specification of category 01
2
2
11
The pressed key of the wireless remote commander can
be discriminated by the display data.
14.
Battery voltage check
I
Page 2
I
Category 01
I
Address 15
Display Data
Battery Voltage
FF
Approx. 1 0 Vdc
FO
Approx. 9.4 Vdc
EO
Approx. 8.8 Vdc
DO
Approx. 8.2 Vdc
co
Approx. 7.5 Vdc
80
Approx. 6.9 Vdc
AO
Approx. 6.3 Vdc
90
Approx. 5.6 Vdc
80
Approx. 5.0 Vdc
Using method:
Order
Page
Address
Data
Procedure
2
00
01
Specification of category 01
2
2
15
The battery voltage can be discriminated by the dis Ia
data.
p y
*
Voltage measureme nt accuracy
IS
approx.
±
10%.
-215-