7-2-20. Page D Data Modification 2
After the camera adjustment, change the data of page D and address
01 to the following:
EVI-D30 (NTSC)
EVI-D31 (PAL)
Data: 04
Data: 05
7-2-21. Page 5 Data Initialization
Initializing method:
1) Page: B. address: 00, data: O01.
2}
Check that the data of page: B, address: 02 is 00.
3) *EVI-D30 (NTSC)
Set data: 80 to page: B, address: 01 and press the PAUSE
button of the adjusting remote commander.
¢ EVI-D31 (PAL)
Set data: 81 to page: B, address: 01 and press the PAUSE
button of the adjusting remote commander.
4) Check that the data of page: B, address: 02 is 01.
5) Turn off the main power supply once.
7-2-22. Home Position Adjustment
Home position adjustment for Pan-Tilter is performed automatically.
Adjustment Address
50, 51, 52, 53, 54, 55, 56, 57, 58, 59
Adjusting method:
;
1) Set data: 01 to page: B, address: 00.
2) Check that the data of page: B, address: 02 is 00.
3) Set data: 10 to page: B, address: 01 and press the PAUSE button
of the adjusting remote commander.
4) Check that the data of page: B, address: 02 is 01.
5) Set data: 40 to page: 5, address: SE and press the PAUSE button
of the adjusting remote commander.
6) Turn off the main power supply once.
Note:
When the camera block has been removed from the pan tilt
mechanism chassis, be sure to perform Home Position Ad-
justment.
7-3. ELECTRICAL BLOCK CHECK
7-3-1. MIC IN/AUDIO OUT Check
Checking method:
1) Input a sine wave of — 66dBs and 1kHz to the MIC IN on the
rear of the set.
2) Connect level meter to AUDIO OUT on the rear of the set and
measure the level.
3) The output level should satisfy the specified value.
7-3-2. Pan Tilter Operation Check
Checking method:
1) Use the infrared remote commander or VISCA to send the com-
mands to move the pan tilter horizontally and vertically.
2) Drive the pan tilter to the top and bottom end points and to left
and right end points.
3) Check that the tilter operates normally.
7-3-3. DATE and TIME Switch Check
Checking method:
1) Simultaneously press and hold down DATE switch and TIME
switch for two seconds to enter the date and time setting mode.
2) Use DATE switch to send "Year" data, then use TIME switch to
determine the year.
3) Repeat step 2) and set "Month", "Days", "Hours" and "Min-
utes".
4) Check that the date and time can be set normally.
7-3-4. Camera No. switch Check
Checking method:
1) Set CAMERA No. switch on the rear of the set to "1". Press
CAMERA No. "1" on the infrared remote commander and press
"P-T RESET" button.
2)
Perform step (1) for CAMERA No. "2" on the set and on the
infrared remote commander.
3) Check that SIRCS LED (ORG) indicator is lit on the front of the
set and the pan tilt reset operation is executed.