3. Serial No. Input

3-1. Company ID Input

Write the company ID in the EEPROM (nonvolatile memory).
Page
Address
Note: The data of page: 0, address: 10 must be "00".
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: C, addresses: E0 to E4.
Note: Press the PAUSE button of the adjustment remote commander
each time to set the data.
Address
Data
E0
E1
E2
E3
E4
3)
Select page: 0, address: 01, and set data: 00.
3-2. Serial No. Input
Write the serial No. and model code in the EEPROM (nonvolatile
memory). Convert the serial No. on the name plate from decimal to
hexadecimal, and write in the EEPROM.
Page
Address
Note: The data of page: 0, address: 10 must be "00".
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Read the serial No. on the name plate, and take it as D
Example: If the serial No. is 77881.
D
=77881
1
Note: Use six digits of the low rank when a serial No. is more than
seven digits.
3)
Obtain D
and H
corresponding to D
2
1
Example: If D
D
= D
2
H
= FE
1
4)
Input H
to page: C, address: E5. (Model code input)
1
Example: If H
Select page: C, address: E5, set data: FE,
andpress the PAUSE button.
5)
Obtain the maximum decimal not exceeding D
3-3, and take this as D
Example: If D
D
= 12288
3
6)
Obtain the hexadecimal corresponding to D
3, and take this as H
Example: If D
H
= 3000
3
DCR-PC350/PC350E
C
E0, E1, E2, E3, E4
08
00
46
01
02
C
E5, E6, E7
from Table 6-3-2.
1
is "77881".
1
– 65536 = 12345
1
is "FE".
1
from Table 6-
2
.
3
is "12345".
2
from Table 6-3-
3
.
3
is "12288".
3
7) Obtain the difference D
(Decimal calculation, 0
D
= D
– D
4
2
Example: If D
8) Convert D
4
(Refer to "Hexadecimal-decimal conversion table" in "6-4.
Service Mode".)
Example: If D
9) Input the upper 2 digits of H
Example: If H
10) Input H
to page: C, address: E7.
4
Example: If H
11) Select page: 0, address: 01, and set data: 00.
D
(Decimal)
1
000001 to 065535
065536 to 131071
131072 to 196607
196608 to 262143
262144 to 327679
327680 to 393215
393216 to 458751
458752 to 524287
524288 to 589823
589824 to 655359
.
1
655360 to 720895
720896 to 786431
786432 to 851967
851968 to 917503
917504 to 983039
983040 to 999999
6-51
between D
4
D
255)
4
3
is "12345" and D
is "12288".
2
3
D
=12345 – 12288 = 57
4
to hexadecimal, and take this as H
is "57".
4
H
=39
4
to page: C, address: E6.
3
is "3000".
3
Select page: C, address: E6, set data: 30, and
press the PAUSE button.
is "39".
4
Select page: C, address: E7, set data: 39, and
press the PAUSE button.
H
1
D
(Decimal)
2
(Service model code)
D
FE
1
D
– 65536
FE
1
D
– 131072
FE
1
D
– 196608
FE
1
D
– 262144
FE
1
D
– 327680
FE
1
D
– 393216
FE
1
D
– 458752
FE
1
D
– 524288
FE
1
D
– 589824
FE
1
D
– 655360
FE
1
D
– 720896
FE
1
D
– 786432
FE
1
D
– 851968
FE
1
D
– 917504
FE
1
D
– 983040
FE
1
Table 6-3-2.
and D
.
2
3
.
4
(Hexadecimal)

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Dcr-pc350e

Table of Contents