Installation

Foundation

The following information are guidelines only
and are not intended to be used as foundation
specifications.
The floor should be level within ±0.5 in. and
made of reinforced concrete (not asphalt) no less
than 4 inches thick. If the existing floor is not of
sufficient thickness or is not level, a new floor
should be poured.
The soil under the concrete floor must be well
settled so the load of the machine and the floor
do not cause further settling. This is especially
important when pouring a new floor.
Newly poured concrete floors need ample time
to cure before installing the machine.
Routing of in-floor conduits or utility trenches
must be done in a manner not to weaken the
flooring the area or the machine.