Download Print this page

netvox R313WA User Manual

Wireless 2-gang seat occupancy sensor
Hide thumbs Also See for R313WA:

Advertisement

Quick Links

Wireless 2-Gang Seat Occupancy Sensor
Seat Occupancy Sensor
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology and is issued in
strict confidential and shall not be disclosed to others parties in whole or in parts without written permission of NETVOX
Technology. The specifications are subjected to change without prior notice.
Wireless 2-Gang
R313WA
User Manual
Model: R313WA

Advertisement

loading

Summary of Contents for netvox R313WA

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology and is issued in strict confidential and shall not be disclosed to others parties in whole or in parts without written permission of NETVOX Technology. The specifications are subjected to change without prior notice.
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ....................2 2. Appearance ....................2 3. Main Features .................... 3 4. Set up Instruction..................3 5. Data Report ....................5 6. Seat Occupancy Delay Configuration ............8 7. Installation ....................10 8. Important Maintenance Instruction ............11...
  • Page 3: Introduction

    1. Introduction R313WA is a Class A wireless 2-gang seat occupancy device based on standard LoRaWAN protocol. The R313WA will report to the gateway whenever one of the 2-gang seat occupancy sensor detects external pressure. It will also report to the gateway when the external pressure is gone.
  • Page 4: Main Features

    3. Main Features  Compatible with LoRaWAN  2 sections of 3V CR2450 button battery power supply  Detectable voltage and seat occupancy status  Simple operation and setting  Protection level IP30  Compatible with LoRaWAN Class A  Frequency hopping spread spectrum technology ...
  • Page 5 Network Joining Turn on the device to search the network. Never joined the network The green indicator stays on for 5 seconds: success The green indicator remains off: fail Turn on the device to search the previous network. Had joined the network The green indicator stays on for 5 seconds: success The green indicator remains off: fail Fail to join the network...
  • Page 6: Data Report

    * DisableTime must ≧5s , Detection Time must ≧ DisableTime . Pressure detecting: R313WA is equipped with two-gang seat occupancy sensor. When the seat occupancy sensor detects changes with the pressure status R313WA will report. When the seat is taken, report 1. When the seat is not taken, report 0.
  • Page 7 0x01 DisableTime DectionTime (2bytes Unit:s) (2bytes Unit:s) (1byte Unit:0.1v) ReportReq (2bytes Unit:s) (2bytes Unit:s) Config Status Reserved 0x81 (0x00_success) (8Bytes,Fixed 0x00) ReportRsp R313WA 0x5A ReadConfig Reserved 0x02 (9Bytes,Fixed 0x00) ReportReq ReadConfig Sensor Sensor MinTime MaxTime BatteryChange 0x82 DisableTime DectionTime (2bytes Unit:s) (2bytes Unit:s) (1byte Unit:0.1v)
  • Page 8 Example#1 based on MinTime = 1 Hour, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange=0.1V Max Time Max Time leeping (Min Time) leeping (Min Time) Wakes up and Wakes up and Wake up and collects data collects data collects data REPORTS 2.8V REPORTS 2.8V REPORTS 2.8V Note:...
  • Page 9: Seat Occupancy Delay Configuration

    DetectionTime is the detecting period. (Please find further info regarding DisableTime and DetectionTime below.) (1) When R313WA detects pressure caused by the occupancy of the seat, it will report 1 (indicating the seat is taken) and other status (battery for example).
  • Page 10 While DetectionTime is 60 secs and DisableTime is 30 secs, pressure is detected during 25th sec. R313WA will restart pressure detect procedure (DetectionTime). No pressure is detected during next DetectionTime and R313WA therefore report un-pressure Triggered DetectionTime = 60 secs...
  • Page 11: Installation

    (occupancy delay configuration,default:30s, can the surface to affect the adhesion of the device. modify) ,R313WA will report un-pressure 2. Do not install the device in a metal shielded box or Note: other electrical equipment around it to avoid affecting When the seat is taken, report 1.
  • Page 12: Important Maintenance Instruction

    8. Important Maintenance Instruction Your device is a product of superior design and craftsmanship and should be used with care. The following suggestions will help you use the warranty service effectively. • Keep the equipment dry. Rain, moisture, and various liquids or moisture may contain minerals that can corrode electronic circuits.