When this message is received, Rx.HRPN will set OH.
This message will not be received when "SysEx" parameter of "MIDI Rx Sw" group = OFF.
'Moke on interval of S0ms or more, hefore receiving the next message.
it GS mode
This model will be in un operational mode of "Patch Table 1" when receiving this message.
'Status
Data byte
Status
FOH
41H, dev, 42H, 12H, 40H, OOH, 7FH, 7FH, 424
FH
Byte
Description
FOH
Exclusive status
a
'D number (Roland)
dey
Device 1D (dev: OON — 1FH (1 — 32), Initial value is 10H {17)}
42H
Model IB (6S)
TH
Command 1D (O11)
AGH
Address MSB
OOH
Address
TH
Address LSB
TH
Data {Exit 6S mode)
42H
Check sum
ETH
EDX (End OF Exclusive)
This message wl not be received when "Exclusive" parameter of MIDI Rx Sw" group = OFF.
Make an interva! of 5Oms or mare, before receiving the next message.
2. TRANSMIT DATA
System realtime
° Active sensing
status
FEH
This message i transmitted with 250 mili seconds interval,
© System exclusive message
status
dota bytes
FOH
iH, ddk,...eeH
FH
FOH: System exclusive
manufacturer #0: 41H (65)
dd, ..., ee = Dota: OOH — 7FH (0 — 127}
FTH: FOX (End of Exclusive/System common)
Refer fo section 3,4.
3. Exclusive
communications
The Sound Expansion Series can send ond receive paich parameter, elc using the system exclusive message.
The model 1D code of the Sound Expansion Series s 46H. The device ID code is to be determined by the "Device 10"
setting of Master.
The Sound Expansion Series ignores GS exclusive message other than "GS reset," "Exit 6S made" and "Scale tune
poramefer," General MIDI system on, General MIBI system off, GS reset and Exit 65.
The model iD of the G5 is 42H.
One way communication.
* Request data 1 RQT (11H)
Bytes
Description
Fol
Exclusive status
4a
Manufocturer 1D (Roland)
Dev
Device 1D
46H
Model 1D {Sound Expansion Series}
a
Commond
1D (RQ.1)
cal
Address MSB
bbH
Address
ccH
Address
ad
Address LSB
ss
Size MSB
tH
Size
wut
Size
wit
Size LSB
sum
Check sum
FH
FOX {End of exclusive)
Receive only: the Sound Expansion Series does not send this message.
MIDI IMPLEMENTATION
12H
Sound Expansion Series (MODEL ID = 46H)
Manufacturer (0 (Roland)
4qH
Dev
Device 1D
46H
Model 1D
12H
Command ID (DT 1}
ail
Address MSB
bhH
Address
cl
Adress
dd
Address SB
eel!
Dota
ff
Data
sum
Check sum
FH
£OX {End of exclusive)
2. GS (MODEL ID = 42H)
Bytes
Description
FOH
Exclusive status
4i
Manufacturer (0 (Roland}
Dev
Device ID
4a
Model ID (GS)
v2H
Command ID (DTH)
onl
Address MSB
bbq
Address
cH
Address
col
Data
HH
Data
sum
Check sum
FH
EOX (End of Exclusive)
Note: When the device {D is 7FH, Sound Expansion Series con receive the exclusive message even if the unit number
is enything,
* Parameter address map
Address and size are configured in 7 bits, hexcdecimal notation.
Address
SB
iB
Binary
Gooa nega §— Ohbb bbb
eee cee
Odd ddd
Phitshex
AK
BB
ice
BD
Size
ASB
LSB
Binary
sss ssss
Ott HH
Quy uuu = Gv wwe
Thitshex
SS
ais
UU
Ww
¢ Parameter base address
1) A pair of two addresses preceded by the symbol # represents a divided — by -two dats, e.g.the dota ABH (hex) is
divided into OAH ond OBH and seat in that order.
2) Porameter associated with address following the symbol % are for Sound Expansion Series
* Example of exclusive data
Dita Set I (1 byte dota)
To Select Pan-Delay for the Reverb Type.
FO 41 10 46 1206 00 10 OB 07 SC FT
Note that the Sth byte value is 12H in order fo "Set" the date,
Send the data (07 for Pon-Delay) with the address (00 00 01 OD for reverb type) of the "Performance common"
porometer.
Data set 1 (2 byte data)
To Select Wave Number 141 for Patch Tone 1 in Past 1.
FO 4] 10 46 12:00
00 28 01 08 0C 43 F7
The Address For Patch Tone 1 in Part | is 00 00 28 01.
If you wont to send 140 as a data, first you need to change it to hex-decimal notation which is BC.
Then divide this in 2 byte, which is called "nibblizing" , and send 08 OC os data.
Request Data
Hake the module to send the chorus level.
FO 41 10 46 11 00-00 10 12 00:00:90 01 5D F7
Hote that the Sth byte value is 17H, in order to "Request" the date.
'Send 00 69 10 12 as an Address for Chorus Level and 00 00 00 O1 as "Size of the data" for it, which is 1 byte.
'When the module receives this data, it will automatically send bock the following data from MIDI OUT.
FO 41 10 46 1200 00 10 12 3 22 7
15