TT
a
ronan
ere ed
@ Error Messages
Whenever
an operation is incorrect, or if data cannot be
processed correctly, an error message will appear in the display.
Consult the following list and take the appropriate action.
bos}
OC L. evap Butter Ful
Cause
: The memory backup battery inside the M-GS64 has
run down.
Action
— : Consult a nearby Roland Service Station.
[~
Ee SE
(Check Sum Error)
Cause
: The check sum of the received exclusive message is
incorrect.
Action
—: Check the data which was transmitted to the M-GS64
, and transmit it once again. Also make sure that the
MIDI cable is not damaged.
Ll
CO
L. (inp Buffer Full)
Cause
: An excessively large amount of MIDI data was
received by the M-GS64 all at once, and correct pro-
cessing could not be carried out.
Action
—: Avoid having large amounts of MIDI data be trans-
mitted all at once.
}
BEL (MIDI Off Line)
Cause
1: It is possible that the power has been turned off for
the MIDI device connected to MIDI IN
Action 1 : The problem is not with the M-GS64 . Check the
power of the connected MIDI device.
Cause2
: A MIDI cable may have been pulled out, or has dam-
aged internal elements.
Action 2: Check the MIDI cables.
m0 > (No Patch)
Cause
: A Patch which the M-GS64 does not have has been
selected.
Action
: Check the Bank number and Program number by
which the sound (Patch) is selected.
PIO
G
{No Drum Set)
Cause
: A Drum Set which the M-GS64 does not have was
specified.
Action
—: Check the Program number by which the Drum Set
is selected.
is h
(Out/Thru: Thru)
Cause
: Since the MID] OUT/THRU
connector is set to
THRU, the Bulk Dump cannot be carried out.
Action
: Set OUT/THRU Select (p. 18) to OUT.