Id
Parameter
Parameter
Central heating
t0
ignitions timer
Central heating ramp
t1
timer
CH ignition delay
t2
from TA and CR
request
t3
Display lighting
t4
Display
Description
The boiler has electronic timing, which prevents the burner from
igniting too often in central heating mode (with step of 10)
In the ignition phase, the boiler performs an ignition ramp in order
to arrive at the maximum power set (with step of 10)
The boiler is set to switch-on immediately after a request. In the case
of particular systems (e.g. area systems with motorised thermostatic
valves etc.) it could be necessary to delay switch-on (with 10 step)
Establishes the display lighting mode.
0 Automatic: the display lights up during use and dims after 15
seconds of inactivity. In the event of an anomaly the display flashes.
1 Low: the display is always lit with low intensity
2 High: the display is always lit with high intensity.
Establishes what the indicator displays 14 (Fig. 37).
"Summer" mode:
0: the indicator is always off
1: circulator active, it displays the flow temperature
pump off the indicator is off
"Winter" mode:
0: it always displays the value set on the central heating selector
1: circulator active, it displays the flow temperature
pump off always displays the value set on the CH selector
Personalized
Range
Default
0 - 600
18
seconds
0 - 840
18
seconds
0 - 600
0
seconds
0 - 2
0
0 - 1
1
value
55