Automatic Electronic Flash
Model 283
6.
TROUBLE:
Light output not
according
to
specifications,
automatic
mode-auto circuit not function-
ing
correctly.
ACTION
INDICATION
REMARKS
A.
Adjust
auto circuit
via
R26
(see
Sec.
4
.2.9)
Light
output to
Problem
solved
specifications
Light
output cannot
Go to step
B
be brought
to
speci-
fications
B.
Check with test
sensor
Light output as
Problem solved
specified
Problem
not
Go to
step
C
corrected
c. Observe
OT1
;
if not firing,
short SCR3
between
OTl
fires
Go to step
D
anode and cathode momentarily
If it
still does not
Check
quench trigger
fire
capacitor
Cl
9,
quench-
t ube
OTl
,
or
quench
trigger
transformer Tl
.
Replace
as
necessary.
If
still not
firing, check
power supply to
R28,
R29,
and
R31
.
D.
Replace SCR3
Light
output as
Problem
solved
specified
Problem
not
Go to step E
corrrected
E.
Replace
zenor diode
D12
Light
output
as
Problem
solved
specified
Problem not
Check auto and quench
corrected
circuit
components
1.
TROUBLE
:
Sufficient light
indicator
(green
light)
not
functioning-
auto circuit working.
ACTION
INDICATION
REMARKS
A.
Check
lamp DS3
GOOD
Go to step B
Does not light
Replace
lamp
DS3
B.
Check
D9
and
C10
for open circuit
GOOD
Check
R
14 for open
BAD
Replace
diode
D9
or
c
10
Vivi tar
37460598
(11
/80)