Automat
ic Electronic Flash
Model 283
2.
TROUBLE:
Ready light on, but not
blinking-
battery saver not functioning .
ACTION
"
INDICATION
REMARKS
,
A.
Check battery
voltage,
contacts, and ter-
GOOD
G6
to step B
minals
BAD
Replace,
clean, or re-
position
8
.
Check voltage of main
capacitor C1
(See Sec.
330V
Go to step C
4.2.4
) and
ad
just
if
necessary
Less than
330V;
Go to step D
cannot be adjusted
C.
Replace thyristor SC
R
1
Ready light light
still
Check associated
not blinking
components
D.
Check main capacitor C
1
for leakage
Leaks
Replace
C1
and,
if
ready light
still
doesn't
blink, go to step E
Does not leak
Go to step E
E. Replace diodes D3 and D4
Light does not blink
Check
all
associated
components and wires
3. TROUBLE:
No flash, no ready light, but there is oscillation.
ACTION
INDICATION
REMARKS
A. Check oscillator t ransformer
T
1 output voltage
Average approx.
G.o to step B
Connect
meter
between positive terminal of
130VAC average
main capacitor
C1
and
terminal
5 of
T1
. Use 500V
scale, AC
8
.
Check diodes D3 and D4
GOOD
Go to step C
Open circuit or
Replace
leakage
-
C.
Check main capacitor C1 for leakage (see
Sec.
GOOD
Check PC board
insula-
4.2.5)
tion
for
leakage
Leaks
Replace
Vivi
tar
37460598
(1
1/80)