TROUBLESHOOTING
The charts in this section present step-by-step procedures for determining and correcting some of the most
common troubles that can
occur
with the Vivitar Model 283 Automatic Electronic
Flash.
In t
roubleshoot-
ing,
also refer to the circuit diagram
in Section
5, the principles of operation and circuit descriptions in
Section 2, and the
operational
checkout and electronic component values in 4.2 and 4.3
1.
TROUBLE:
No flash, no ready light, no oscillation.
ACTION
INDICATION
REMARKS
A. Check battery voltage
GOOD
Go to step
B
BAO
Replace batteries
B.
Check battery contacts in cartridge and
ter-
GOOD
Go to
step
C
minals in case for corrosion; check polarity
of terminals
BAD
Clean,
replace or re-
position
c.
Check current draw with power unit
HIGH
Go
t
o
step
F
NONE
Go to step 0
0
.
Check continuity between
terminals
and
GOOD
Go to step
E
PC board; check wires
for
breaks, connec-
tions on board for
good
solder
BAD
Repair or replace
E.
Check
ON/OFF
switch continuity
GOOD
Go to step F
BAD
Replace switch
F.
Check oscillator transistor 01 resistances
GOOD
Go to
step
G
(see Sec. 4.3.2)
BAD
Replace 0
1
G. Check oscillator transformer
T1
(see
Sec.
GOOD
Go to step H
4.3.3 for resistances)
BAD
Replace T
1
H.
Check transistor 02 resistances (see Sec.
GOOD
Go to
step
I
4.3.2)
BAD
Replace 02
I.
Check
all
associated components o
n
PC
GOOD
Check for damaged
board B
components
through-
out
BAD
Replace
component(s)
26