Calibrating The Auto Circuit; Auto Circuit Calibration Specifications - Vivitar 283 Service Manual

Automatic electronic flash
Hide thumbs Also See for 283:
Table of Contents

Advertisement

Aut omatic
Electronic Flash
Model 283
4.2.9
CALIBRATING THE AUTO
CI
RCUIT
To
check
the auto circuit
in
the
four
automatic modes,
set
up
the
unit
at a distance of 6
feet
from the
sensor
of a
pulse
photometer in an environment that is
nonreflective
except for
the
target.
The
target
should
have
a reflectance of
36%
and
measure
a minimum of 4 by
4
feet.
See that
the
unit is optically
level
with
the
tar-
get,
flash it 5
times to assure
full power in
the
main
capacitor, and wait
until the ready
light starts
to
bl
ink.
Set
the
calculator dial of the
unit
on ASA 25, and test the
four
color auto
modes
at the f-stops
indicated
on
the dial. All should test w ithin a tolerance of ±0.5EV.Test
BLUE auto
mode
first,
then RED
,
followed by
YELLOW.
T
his
sequence should require
the least
amount of adjustment once
the
blue
mode
has
been cali-
brated.
Check
PU RPLE mode
last.
It
should
fall
within tolerance.
The appropriate
f-stops at
ASA
25 and
the
permissible
upper and lower limits of the tolerance in f-stops and
lux-seconds
are as follows:
Table 4-2.
A uto Circuit Calibration Specifications
BLUE
f4.0
Variance
from Spec. (EV)
f-stop
lux/sec
+0.5
=
4.75
=
173.0
0
=
4.0
=
123.0
-0.5
=
3.36
=
87.0
RED
f2.0
Variance from Spec.
(EV)
f-stop
lux/sec
+0.5
=
2.38
=
43.5
0
=
2.0
=
30.8
-
0.5
=
1.68
=
21.7
YE
LLOW
f1
.4
Variance
from
Spec.
(EV)
f-stop
lux/sec
+0.5
=
1.68
=
approx.
21 .7
0
=
1.4
=
approx.
15.1
-0.5
=
1.18
=
approx.
10.6
PURPL
E
f5.6
Variance from Spec. (EV)
f -stop
lux/sec
+0.5
6.66
341
.0
0
5.6
241 .1
-0.5
4.71
170.5
Adjust the auto
modes
by turning pot R26 (at
hole "F").
To
lower
lux/sec reading,
turn
counterclock-
wise, to
raise,
clockwise. (Fig. 4-1)
20
Vlvlter
374
60598
(11
/80)
-