D.
If the
leakage
current is greater than
1mA,
main capacitor C1 should be replaced .
330
voe
Power Supply
Resistor
1
K Ohm
1%,
2W
Switch
Closed
Capacitor
1100mFd.
330WV
Figure
4-3.
Main Capacitor Leakage Test
4.2.6
NEON INDICATOR.
The neon
indicator
NE1 should light when the
voltage
across the main capacitor
C 1 reaches
the
following potential:
For units whose serial number has the first 3 digits
below 606
above 606
240VDC
+
15VDC
260VDC
+
1 OVDC
4.2.7
RECYCLE TIME.
The
time to
recycle
to the
neon indicator voltage (given
in paragraph 4.2.6)
will
de·
pend on the operational mode and the type
of
power
supply.
Table 4-1.
Recycle Time
Power
Supply
Mode
Recycle Time (seconds)
DC, batteries
NiCad, fully charged
Manual
4 to 5
Auto
0.5 to 5
Alkaline, fresh
Manual
7
to
9
Auto
0.5 to
9
HVP
Manual
2 to 3
Auto
0.5 to 3
AC,
with
SB-4 adaptor
Manual
8
Auto
0.5 to 7
4.2.8
FULL POWER
LIGHT
OUTPUT
CHECK.
If components that may affect the
light output
have
been replaced, or there is
some
question concerning this check it with a pulse photometer. In the manual
mode,
full
power output at the rated Guide Number should be 277
lux-seconds.
The allowable variation,
however,
can
be minus
an
f
-stop,or as
low as 138
lux
-seconds, when .measured
10
feet
from
the photo-meter
sensor.