4-3. Replacing the fuse

DANGER :
In order to prevent accidents due to an electrical shock, be sure to turn OFF the power switch and
remove the power plug from the receptacle before replacing the fuse. In addition, be sure to attach
the rated fuse.

4-4. Replacing the gripper tube

WARNING :
Turn OFF the power before starting the work so as to prevent accidents caused by abrupt start of
the sewing machine.
In addition, close the air valve before replacing the tube.
– 37 –
Carry out the following steps of procedure to replace
fuse ❶ of the device.
1)
Turn OFF the power switch and wait for five or
more minutes.
2)
Remove the cover of control box for the device.
Replace fuse ❶ attached on the PCB with a
3)
new one. Use the fuse with a specified capacity
(HF0037060PA,125V/T6A).
4)
Attach the cover removed in step 2) back in
place.
If the air tube at the gripper has worn out or is dam-
aged, replace it with a spare tube supplied with the
unit as an accessory following the steps of proce-
dure described below.
Detach hose nipple ❶ from the rear end of grip-
1)
per. Then, detach the tube.
Detach the other end of tube from joint ❷ .
2)
3)
Connect a new tube following the aforemen-
tioned steps of procedure in the reverse order.