OPERATION CHECK-3
CONTROL OF POWER SUPPLY (OUTPUT SENSOR AND THERMAL SENSOR)
[When]
1. Exchange the power transistors (Q6050 - 6056, Q6060 - 6066, Q6080 - 6086, Q6090 - 6096).
2. Exchange the power amplifier PC board ass'y (NAAMP-9061, 9062, NACLA-9063 - 9069).
3. Exchange the thermal sensor PC board ass'y (NAETC-9042, 9043).
[Procedure]
<Note>
No output. No input.
Output sensor
1. Press and hold down CD button, then press ON/STANDBY button while the unit is powered on.
" Test - _ " is displayed only for 5 seconds.
Te s t - _
2. Press GAME/TV button while " Test - _ " is displayed.
The unit will be in the state of " Test-4-00 ".
Te s t - 4 - 0 0
+
3. Repeatedly press TONE
Te s t - 4 - 3 7
4. At this time, confirm that the red characters of " FM STEREO " is displayed.
Te s t - 4 - 3 7
5. Press ON/STANDBY button.
C l e a r
Thermal sensor
1. Press and hold down DISPLAY button, then press ON/STANDBY button when the unit is powered on.
The main microprocesor version will be displayed only for 3 seconds.
<Ex.>
2. Press TONE button while the version is displayed. The temperatures of two thermal sensors (Q6380, Q6381) will be displayed.
<Ex.>
3. Confirm that the displayed temperature is within +/-20 C from the ambient temperatures.
4. Press ON/STANDBY button.
C l e a r
Blinks
button until " Test-4-37 " is displayed.
FM STEREO
M a in :
9 1 .0 1 / 0 8 8 0 1 A
Unit is C
T: 2 2 / 2 3 F : -
V: 0 .0 0
S E C : H