I P T E S T PA R A M E T E R S
Following any repair or maintenance procedure that requires disassembly of the fixture, use
Elation's IP Tester to confirm the IP integrity of the fixture. The air valve is located on the
back panel next to the display screen, as shown in the diagram below. Please contact Elation
Service for information regarding the Elation IP Tester, or visit the product information page
online at:
https://www.elationlighting.com/ip-tester
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST! AVOID
PLACING YOUR FACE, EYES, HANDS, ETC IN PROXIMITY TO THE LENS OF THE
FIXTURE WHILE PERFORMING THE TEST!
DE-HUMIDIFICATION: IP65 fixtures operating in high-humidity environments may experience
residual fogging or condensation. Such fogging will not affect the fixture, and can be removed
using the following procedure: position the unit with the air valve pointing upwards, then open
the air valve and run the unit for 1-2 hours after reaching operating temperature. Then, while
the fixture is still hot, re-install the air valve and allow the unit to cool down. Please note:
this procedure should be performed in a dry, climate-controlled environment. Avoid additional
fogging by drying the fixture completely before placing into a road case.
Elation Product
Elation Six+ PAR S
www.elationlighting.com
POWER IN
AC100-240V 50/60Hz
POWER OUT
FUSE:T2A/250V
MAX:100-240V 11A
Minimum
Maximum
Value
Value
Kpa
Psi
Kpa
20
3
23
Pressure Valve
DMX OUT
DMX IN
Inflation
Balance
Time
Time
Psi
S
S
3
30
15
11
Inspection
Leakage
Time
S
Pa
15
>100