TESTING A PEN
1. While observing the P
the tablet active area. A value for
number) should be displayed. If you have more than one tablet connected to your system, be sure you
have selected the T
2. Move your tool along the tablet surface. The X and Y D
position.
3. Test your Intuos4 pen switches. A tablet status LED should brighten each time you click with the tool tip,
press the side switch, or press the tool's eraser to the tablet.
•
Click on the tablet surface with the tool tip – the S
(P
should change from approximately 0% with no pressure applied to approximately 100%
RESSURE
when full pressure is applied.)
•
Press the side switch without pressing the tip to the tablet – the S
(For the Intuos4 pen, do this for both positions of the DuoSwitch.)
Pen
Airbrush
•
Press the tool's eraser to the tablet – the S
(Pressure should change from approximately 0% with no pressure applied to approximately 100%
when full pressure is applied.)
•
For the Airbrush, move the fingerwheel forward – the W
approximately 0 when the fingerwheel is all the way forward. Move the fingerwheel backward – the
W
value should increase to approximately 1000 when the fingerwheel is all the way back.
HEEL
4. Test tilt for the x-axis by moving the pen from a vertical position toward the right; the X T
change from approximately 0 to +60. Now move the tool to the left of vertical; the X T
change from approximately 0 to -60.
5. Test tilt for the y-axis by moving the pen from a vertical position toward the bottom of the tablet; the Y T
value should change from approximately 0 to +60. Now move the tool toward the top of the tablet; the Y
T
value should change from approximately 0 to -60.
ILT
6. If you are testing an Art Pen, test pen rotation by holding the pen vertically and twisting it around its axis.
The displayed R
OTATION
7. When you are done, click on the C
Contents
D
I
OINTING
EVICE
NFO
P
ROXIMITY
for which you are testing your tools from the T
ABLET
Tip = 1
DuoSwitch (lower position) = 2
DuoSwitch (upper position) = 3
Eraser = 1
Tip = 1
Side Switch = 2
Eraser = 1
value should change.
button to exit the dialog box.
LOSE
Contents
Index
column, bring your Intuos4 tool within 10 mm (0.39 inch) of
, the D
N
, D
EVICE
AME
values should change to reflect the tool
ATA
state and P
WITCHES
state and P
WITCHES
HEEL
Index
T
, and a D
EVICE
YPE
EVICE
I
column.
ABLET
NFO
value should change.
RESSURE
state should change.
WITCHES
value should change.
RESSURE
value should decrease to a value of
ILT
57
S/N (serial
value should
ILT
value should
ILT
57