Control Buttons
The control buttons on the pendant and at the landing call stations are
constant-pressure type. This means you must press and hold the button to
operate it. Release the button to stop the function. The emergency STOP
button is push/pull.
Note that you need a key to activate the controls on the platform control panel
and at the landing call station (if the call station is equipped with a key switch).
Never use the lift if the control buttons do not work in
constant-pressure mode.
The landing call/send stations are hard-wired with up, down, fold and unfold
control buttons.
Emergency STOP Button
When you press the red
emergency STOP button on
the platform control panel
(shown in Figure 4), the lift
will stop immediately. To
release the emergency
STOP button, press and
turn it slightly clockwise.
Check the emergency STOP button operation weekly. If
the lift does not stop when the button is pressed, DO NOT
use the lift. Contact your authorized dealer.