7
Technical data
7.1
T drive 4 Rob 2
Performance specifications and guarantee only in connection with original spare and
replacement parts!
Supply voltage
Max. welding current at 60% DC
Wire feed speed
Standard WF roller fitting
Drive
Protection classification
Ambient temperature
Dimensions (LxWxH) [mm]
Weight
EMC class
Constructed to standard
099-000077-EW501
09.02.2011
NOTE
42 VAC
550 A
0.3 m/min to 10 m/min
1.0 + 1.2 mm (for steel wire)
4-roller (37 mm)
IP 23
-20 °C to +40 °C
395 x 210 x 235
7.5 kg
A
IEC 60974-1, -5, -10
/