Daikin SV1A25AJV1B User Reference And Installation Manual page 46

Safety valve unit
Hide thumbs Also See for SV1A25AJV1B:
Table of Contents

Advertisement

13
|
Special requirements for R32 units
Lowest underground floor
350
340
330
320
310
300
290
280
270
260
250
240
230
220
210
200
190
No safety measure
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
5
10
15
20
25
m [kg]
Lowest underground floor
No safety measure
(c)
5
15
6
18
7
21
8
24
9
27
10
30
11
33
12
36
13
39
14
42
15
45
16
48
17
51
18
54
19
57
20
60
21
63
22
66
23
69
24
72
25
75
26
77
27
80
28
83
29
86
30
89
31
92
32
95
33
98
34
101
35
104
36
107
37
110
38
113
39
116
40
119
41
122
42
125
m Total refrigerant charge in the system [kg]
A
Minimum room area [m²]
min
(a) Lowest underground floor (=Lowest underground floor)
(b) All other floors (=All other floors)
(c) No safety measure (=No safety measure)
(d) External alarm OR Natural ventilation (=External alarm OR Natural ventilation)
(e) Ventilated enclosure (=Ventilated enclosure)
(f) Ventilated enclosure OR External alarm + natural ventilation (=Ventilated enclosure OR External alarm + natural
ventilation)
Installer and user reference guide
46
(a)
(c)
Ventilated enclosure
30
35
40
45
50
55
60
65
m [kg]
A
[m²]
min
All other floors
(a)
External alarm OR
No safety measure
Natural Ventilation
(d)
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
62
64
66
68
70
72
74
76
77
79
81
83
350
340
330
320
310
300
290
280
270
260
250
240
230
220
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
(e)
60
50
40
30
20
10
0
70
75
80
5
10
15
m [kg]
(b)
No safety measure
(c)
10
43
128
12
44
131
14
45
134
16
46
137
18
47
140
20
48
143
22
49
146
24
50
149
26
51
152
28
52
154
30
53
157
32
54
160
34
55
163
36
56
166
38
57
169
40
58
172
42
59
175
44
60
178
46
61
181
48
62
184
50
63
187
190
52
64
54
65
193
56
66
196
58
67
60
68
62
69
64
70
66
71
68
72
70
73
72
74
74
75
76
76
77
77
79
78
81
79
83
80
All other floors
(b)
No safety measure
(c)
Ventilated enclosure
OR
External alarm + natural ventilation
20
25
30
35
40
45
50
m [kg]
A
[m²]
min
Lowest underground floor
(a)
External alarm OR
(c)
Natural Ventilation
(d)
85
87
89
91
93
95
97
99
101
103
105
107
109
111
113
115
117
119
121
123
125
127
129
131
199
133
202
135
205
137
208
139
211
141
214
143
217
145
220
147
223
149
226
151
229
153
231
154
234
156
237
158
(f)
55
60
65
70
75
80
All other floors
(b)
No safety measure
(c)
85
87
89
91
93
95
97
99
101
103
105
107
109
111
113
115
117
119
121
123
125
127
129
131
133
135
137
139
141
143
145
147
149
151
153
154
156
158
SV1A25AJV1B+SV4~8A14AJV1B
VRV 5 safety valve unit
4P749917-1 – 2023.09