Daikin Control unit RoCon BF, EHS157034, EHS157068
Operating instructions
English
Daikin Control unit RoCon BF, EHS157034, EHS157068
Daikin 
RoCon BF
EHS157034
EHS157068

Advertisement

Table of Contents
loading

Summary of Contents for Daikin RoCon BF

  • Page 1 Operating instructions Daikin Control unit RoCon BF, EHS157034, EHS157068 Operating instructions English Daikin Control unit RoCon BF, EHS157034, EHS157068 Daikin  RoCon BF EHS157034 EHS157068...
  • Page 2: Table Of Contents

    Errors and faults ..... 52 unit to the Daikin heat generator ....31 Detecting errors and rectifying faults.
  • Page 3 Notes....... . . 61 10 List of keywords ..... 63 Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 4: General Safety Precautions

    ● Work on the Daikin heat generator (such as set-up, servicing, connection and initial start-up) must only be carried out by persons who are authorised and who have successfully completed quali- fying technical or vocational training and who have taken part in advanced training sessions recognised by the relevant responsible authorities for the specific activity.
  • Page 5: Observing The Instructions

    Disregarding this warning can cause damage to property and the environment, and result in – the operating manual for the operator. minor injuries. – For connecting to a Daikin solar system: the associated installation and operating This symbol identifies user tips and par- instructions.
  • Page 6: Safety Instructions For Installation And Operation

    1.2.2 Use as intended The RoCon BF control unit must only be used in Daikin oil and gas fired heating units that are re- leased for the Daikin RoCon control system. The...
  • Page 7: Product Description

    Daikin heat generator can be conveniently monitored and operated by remote control using a mobile phone (App). The RoCon BF control unit contains a timer which can be used to set: – 2 individually adjustable switching time programs the room heating (direct heating circuit), –...
  • Page 8: Operation

    If electrical components come into contact with Red: Error status; depending on the type of error, the Daikin heat generator continues to operate with water, this can cause an electric shock as well restrictions. as cause potentially fatal burns or injuries.
  • Page 9: Operating Elements

    Frequently required functions and setting options can be quickly and directly selected using the rotary switch (main function level). Regardless of the rotary switch position, the Daikin heat generator operates according to the operating mode which was set in the "Operating Mode"...
  • Page 10: Operating Concept

    3.4 Basic functions and operating modes (see chap. 3.4.8). 3.4.1 System information (Info) If the system is switched on, the defaults set in the RoCon BF In this rotary switch setting, all system temperatures, the heat control unit fully automatically control the operation of the generator type, various software information and the operating –...
  • Page 11 (t Current temperature of heating return (t Displaying the water pressure On the RoCon BF control unit, the system pressure (water Tdhw Current temperature in the hot water storage tank pressure) of the internal circuit (direct heating circuit) can be dis- DHW1 played when it is switched on.
  • Page 12: Setting The Operating Mode

    3.4.2 Setting the operating mode For an outside temperature below the [T-Frost Protect] parame- The selection of the operating mode in which the Daikin heat gen- ter value, the integrated heating circulation pump is switched on erator is to work is made on the rotary switch in the "Operating to prevent the heating system freezing.
  • Page 13 – No communication error to the firing unit is pending and The resistances specified in tab. 3-6 function in a toler- – the Daikin heat generator has been switched on for at least ance field of 5%. Resistances outside this tolerance 10 min.
  • Page 14: Temperature Setting Of Daytime Room Temperature

    The temperature settings for these time programs are carried out be found in chap. 6.7. via the target value settings "Set Temp Day" , "Set Temp Night" and "DHW Set Temp" Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 15 (see also tab. 3-8). – 1 time program for an optionally connected circulation pump with 3 possible switching cycles Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 16 "Set Temp Night" rotary switch setting. – The hot water generation is not affected. – The time program runs for the set time period from activa- tion. Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 17: System Settings

    In the "Configuration" rotary switch setting, the basic set- tings of the RoCon BF control unit as well as the system configu- ration for the installation environment of the Daikin heat genera- tor, the direct heating circuit, the hot water generation and any optionally connected components are carried out.
  • Page 18 Prerequisite: A valid terminal ID has been assigned to the the remote-controlled device, where "X" is the set device identifi- RoCon B1 control unit of the Daikin heat generator or to the cation of the remote-controlled device. EHS157034 room station .
  • Page 19: Special Functions

    During the emission measurement, the T-HS of the heat gen- erator is limited to the value set in the [Max T-HS] parameter. For additionally connected external heating circuits, the RoCon BF Emission Measurement control unit tries to keep the current T-HS of the heating circuit at Full Load temperatures between 55 °C and 65 °C.
  • Page 20: Manual Operation

    ([T-DHW Setpoint 1]). ● Allow the heat generator to cool down for a If manual operation is ended, the RoCon BF control unit automat- sufficient period of time after the STL test. ically switches to "Standby" operating mode.
  • Page 21: 3-Way Switching Valves Reference Travel

    The STL test can be carried out to check the STL function: 3.6 Special system settings ● Enter the technician code (see chap. 3.6.1). The RoCon BF control unit is already basically configured for the  After entering, the "Setup" level is displayed.
  • Page 22: Heat Slope

    T-Flow Day heating. Configuration ● Prior to initial commissioning, set the Setup maximum temperature limit in the RoCon BF System Configuration control unit ([Max T-Flow] parameter) to the Heat-Slope maximum permitted system temperature prior to starting the emission measurement.
  • Page 23: Weather-Dependent T-Hs Control

    5. Set the rotary switch to the "Operating Mode" position and set the required operating mode (see chap. 3.4). By activating the Air Purge, the RoCon BF control unit starts a clearly defined sequence program with start/stop operation of the...
  • Page 24: Anti-Legionella System

     The parameter overview of the "Basic Configuration" If the Daikin heat generator no longer functions correctly and no level is displayed and the settings can be carried out man- other source for the incorrect behaviour can be determined, it ually according to tab.
  • Page 25: Screed Program

    (screed curing heating) or measures such as me- free work for the heating engineer. A prefabricated heating pro- chanical drying. tocol related to Daikin floor heating can be found in the Internet portal of Daikin. Each screed curing heating must be ordered separately by the client as an extra service in accordance with German con- In this sense, the function heating (identical with "Heating"...
  • Page 26 Screed Program Day 1 25 °C T-HS Screed Day 1 Day 1 25 °C T-HS Screed Day 1 Day 1 26 °C Fig. 3-21 Setting the screed program Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 27: Relay Test

    3.6.10 Remote control via Internet ● Confirm the selection with a brief push of the rotary button. The RoCon BF control unit can be connected to the Internet via  An overview is displayed. an optional gateway (EHS157056). This enables remote control ●...
  • Page 28: Special Function: Switching Contacts

    SmartStart function is not activated. The [HT Protect] parameter (see tab. 6-2) limits the raised target value of the storage temperature. Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 29: Initial Commissioning

    CAN data bus. For this, the RoCon BE1 circuit boards and the a) If no optional RoCon system components are connected RoCon B1 control units of the Daikin heat generator, as well as to the Daikin heat generator, only the RoCon BE1 control...
  • Page 30: Operating Support During Initial Commissioning And During System Extensions

    A maximum of 8 heat generators can be connected in the RoCon system via the CAN data bus. Several heat generators integrated in the heating installation must be regarded as a special application. If necessary contact a Daikin service technician.
  • Page 31: Putting The Daikin Heat Generator Into Operation

    To operate the mixer module directly via the RoCon B1 control unit of the Daikin heat generator, it must have a terminal ID as- signed to it and the terminal function must be activated (see ● Confirm the selection with a brief push of the rotary button.
  • Page 32: Ehs157034 Room Station

    RoCon B1 operating element of the Daikin heat generator. However, not all functions (e.g. manual operation, resetting errors) of the Daikin heat generator can be activated with the room station. A: Configuration for the "Living Room" setting ...
  • Page 33: Allocating The Ehs157068 Mixing Module To A Heat Generator

    Since, in this setting, the RoCon B1 control unit has control over the assigned heating circuit, the settings made on the control unit of the Daikin heat generator only have an effect on the heat gen- erator, but not on the heating circuit (see chap. 4.1).
  • Page 34: Parameter Overview

    ● Rotary switch setting: Info main switch. Language Standard Config Basic Configuration Boiler Function Unmixed Circ Config BUS ID HS Time Master System Config Tab. 5-1 "Basic Configuration" parameters Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 35: After First Commissioning/After Successful Basic

    Screed Error Code IO-CalMax Lerr Screed Program Q-SetpointRoCon IO-Comp PLErr Q-ActualValueRoCon IO-S Burner Starts T-HS FI-T Burner Oper Time Tab. 5-2 Parameters in the "Configuration" rotary switch setting Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 36: Rotary Switch Setting: Dhw Reheating

    Tab. 5-8 Parameters in the "Time Program" rotary switch setting 5.2.8 Rotary switch setting: Remote Param Bus - Scan No selection Contr BM1/BE1 #1 Mix Valve #0 Tab. 5-9 Parameters in the "Remote Param" rotary switch setting Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 37: Parameter Levels For The Ehs157068 Mixer Module

    No function when connected to oil and gas-fired heating units. (Only applicable if the assigned heat generator has a cooling function.) Tab. 5-12 Parameters in the "Configuration" rotary switch setting Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 38: Parameter Settings

    In addition to the above-mentioned functions, the room station can basically be used as a remote control unit of the Daikin heat generator and of the overall RoCon system (with activated terminal function) (see chap.. 4.1 and 4.4.2).
  • Page 39 Setting of the heating circuit ID for the room station (see chap. 4.1). This parameter de- termines which heating circuit should be operated with this value. The direct heating circuit of the Daikin heat generator is set to heat circuit ID "0" as stand- ard (see tab. 6-16, [Unmixed Circ Config] parameter).
  • Page 40: System Configuration" Level

    The burner only starts operating again if the fault has been manually unlocked. To do this, in the event of a fault, a reset parameter is added in this parameter level, which must be set to "On" and confirmed. Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 41: Hc Configuration" Level

    Min T-Flow The determined flow target temperature of the heating circuit is limited to the minimum value 10 - 90 °C 10 °C 1 °C set here. Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 42: Dhw Configuration" Level

    +5 K. The storage loading pump is switched off if the temperature of the heat generator falls below the current hot water target temperature. Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 43: Expert Config" Level (Only Heat Generator A1)

    Overall runtime of the burner in hours, which is stored in the firing unit of the heat generator. Tab. 6-5 Parameters in the "Configuration" rotary switch setting, "Expert Config" level Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 44: Lambda-Gx" Level (Only For The Heat Generator Gcu Compact)

    1]. After the period of time has elapsed, the control unit switches back to the previously active operating mode. Hot water generation is carried out to the then current target value. Tab. 6-7 Parameters in the "DHW Reheating" rotary switch setting Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 45: Rotary Switch Setting: Operating Mode

    Target value of the hot water temperature in °C, which is valid for the 3rd switching time cycle of 10 - 70 °C 58 °C 1 °C the [Automatic 1] and [Automatic 2] time programs. Tab. 6-11 Parameters in the "DHW Set Temp" rotary switch setting Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 46: Rotary Switch Setting: Time Program

    Mix Valve #0 Activation switches to the mixer module with the bus ID X (see chap. 6.13.1, [HC Assignment] parameter). Tab. 6-13 Parameters in the "Remote Param" rotary switch setting Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 47: Rotary Switch Setting: Info

    Depending on the device type, the system configuration and the version of the device software, individual infor- mation parameters listed in tab. 6-14 cannot be dis- played or are displayed at another parameter level. Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 48: Exit Key: Special Level

    Internal hot water generation cannot be used further when operating as a heating module. Unmixed Circ Config Setting of the heating circuit ID for the direct heating circuit of the Daikin heat generator. The Off, heating circuit ID must be unique throughout the entire RoCon system.
  • Page 49: Parameter Levels Of The Ehs157068 Mixer Module

    Solar: Not applicable In addition to the above-mentioned functions, the room controller can basically be used as a remote control unit for the Daikin heat generator and the entire RoCon system (with activated terminal function) (see chap. 4.4.2). Master-RoCon...
  • Page 50: Rotary Switch Setting: Configuration , "Mixer Config" Level

    [Automatic 1], [Automatic 2], [Reducing]. Max T-Flow The determined target T-HS of the heating circuit is limited to the maximum value set here. 20 - 70 °C 50 °C 1 °C Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 51 1st day with the target value setting "- - - -" (see chap. 3.6.7). Tab. 6-18 Parameters in the "Configuration" rotary switch setting, "Mixer Config" level Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 52: Errors And Faults

    Location data (device) of the detected error Data bus address of the device that caused the error Fig. 7-2 Reading the error protocol Fig. 7-1 Display of a current error message Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 53: Deleting Errors, Unlocking The Firing Unit

    Daikin service technician. Please keep the essential device data ready for this (procedure, fig. 7-4): Special Level – Type and manufacturer number of the Daikin heat gener- Special Level ator (see heat generator type plate). STL Test STL Test –...
  • Page 54: Emergency Operation

    Temperature scale, target and target T-HS are displayed. Info 3. Use the rotary button to set the target T-HS.  The Daikin heat generator works manually at the target T- Overview Water Pressure T-HS 4. Cancellation and jump back by pushing the Exit button again.
  • Page 55: Error Codes

    E227 Internal error of the firing unit. Tab. 7-1 Error code of locking faults (can be detected by the firing unit) Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 56 During adjustment, no stable state reached in partial load within the tolerance period (wind effect, speed fluctuations, blower). Tab. 7-2 Error code of non locking faults (can be detected by the firing unit) Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 57 ● Replace sensor/temperature sensor. E100 locking error if the flue gas temperature sensor is ob- ligatory for this heat generator type (e.g. Daikin A1). Burner release only takes place if the fault has been manually unlocked. Temperature sensor in the ●...
  • Page 58: Glossary

    In systems without a circulation line, first the water cooled in the sampling line es- capes during the sampling process until the sampling line has been sufficiently heated by the inflowing hot water. Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 59: Notes

    [T-DHW Setpoint 3]: ____ °C setting Time period Monday Tuesday Wednesday Thursday Friday Saturday Sunday Monday Tuesday Wednesday Thursday Friday Saturday Sunday Tab. 9-2 Individual settings in the hot water timer programs Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 60: Parameter

    Date Comments setting level Tab. 9-4 Individual parameter modifications 9.1.3 Data bus addresses RoCon device Data bus address Comments Tab. 9-5 Data bus addresses in the RoCon system Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 61: Notes

    Notes Notes Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 62 Notes Operating instructions Daikin RoCon Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 63: List Of Keywords

    Standby ....12 Summer ....13 Daikin RoCon Operating instructions Daikin Control unit 008.1543999_00 – 03/2017 – EN...
  • Page 64 008.1543999_00 – EN 03/2017...