To Program An Underfloor Heating Screed Dryout Schedule; To Start An Underfloor Heating Screed Dryout; To Readout The Status Of An Underfloor Heating Screed Dryout; To Interrupt An Underfloor Heating Screed Dryout - Daikin Altherma EHVH/X16S18+26CA Installer's Reference Manual

Low temperature split
Table of Contents

Advertisement

10 Hand-over to the user

T
24h (1)
36h (2)
25°C (1)
35°C (2)
A1
T Desired leaving water temperature (15~55°C)
t Duration (1~72h)
(1) Action step 1
(2) Action step 2
9.6.1
To program an underfloor heating screed
dryout schedule
1 Go to [A.7.2]:
> Installer settings > Commissioning > UFH
screed dryout > Set dryout schedule.
2 Use the
,
,
, and
▪ Use
and
to scroll through the schedule.
▪ Use
and
to adjust the selection.
Result: If a time is selected, you can set the duration
between 1 and 72 hours.
Result: If a temperature is selected, you can set the desired
leaving water temperature between 15°C and 55°C.
3 To add a new step, select "–h" or "–" on an empty line and
press
.
4 To delete a step, set the duration to "–" by pressing
5 Press
to save the schedule.
INFORMATION
It is important that there is no empty step in the program.
The schedule will be executed until a blank step is
programmed OR after 20 consequetive steps.
9.6.2
To start an underfloor heating screed
dryout
INFORMATION
Preferential kWh rate power supply cannot be used in
combination with underfloor heating screed dryout.
1 Go to [A.7.2]:
> Installer settings > Commissioning > UFH
screed dryout.
2 Set a dryout program.
3 Select Start dryout and press
4 Select OK and press
.
Result: The underfloor heating screed dryout starts and following
screen will be shown. It stops automatically when done. To stop it
manually, press
, select OK and press
Tue 15:10
Screed dryout
Current step
1
Remaining
14d 12h
25°C
Desired LWT
Stop
9.6.3
To readout the status of an underfloor
heating screed dryout
1 Press
.
Installer reference guide
60
t
to program the schedule.
.
.
.
2 The current step of the program, the total remaining time, and
the current desired leaving water temperature will be displayed.
INFORMATION
There is limited access to the menu structure. Only the
following menu's can be accessed:
▪ Information.
▪ Installer settings > Commissioning > UFH screed dryout
9.6.4
To interrupt an underfloor heating screed
dryout
When the program is stopped by an error, an operation switch off, or
a power failure, then the U3 error will be displayed on the user
interface. To resolve the error codes, see "12.3 Solving problems
based on error codes" on page 64. To reset the U3 error, your
User permission level needs to be Installer.
1 Go to the underfloor heating screed dryout screen.
2 Press
.
3 Press
to interrupt the program.
4 Select OK and press
.
Result: The underfloor heating screed dryout program is stopped.
When the program is stopped due to an error, an operation switch
off, or a power failure, you can read out the underfloor heating
screed dryout status.
5 Go to [A.7.2]:
> Installer settings > Commissioning > UFH
screed dryout > Dryout status > Stopped at and followed by the
last executed step.
6 Modify and restart the execution of the program.
10
Hand-over to the user
Once the test run is finished and the unit operates properly, please
make sure the following is clear for the user:
▪ Fill in the installer setting table (in the operation manual) with the
actual settings.
▪ Make sure that the user has the CD/DVD and the printed
documentation and ask him/her to keep it for future reference.
▪ Explain the user how to properly operate the system and what
he/she has to do in case of problems.
▪ Show the user what jobs he/she has to do in relation to
maintenance of the unit.
▪ Explain the user about energy saving tips as described in the
operation manual.
11

Maintenance and service

NOTICE
Maintenance should preferably be carried out yearly by an
installer or service agent.
11.1

Maintenance safety precautions

DANGER: RISK OF ELECTROCUTION
ERHQ011~016BA + ERLQ011~016CA + EHVH/X16S18+26CA
Daikin Altherma - Low Temperature Split
4P313777-1C – 2012.11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma erlq011-014-016caAltherma erhq011-014-016ba

Table of Contents