11 Replacement of Lamp Unit

Cautions
· Wait until the lamp is cooled sufficiently before replacing the lamp unit.
· Make sure that all four lamp units are installed.
· Replace of the lamp unit should be carried out by a qualified technician.
11.1. Precautions on Lamp Unit Replacement
Remove the power plug and confirm that the surroundings of the lamp unit have cooled off.
· Be careful when handling a light source lamp. The lamp unit has high internal pressure. If improperly handled, explosion might
result.
· A used lamp unit may burst if it is handled violently.
For disposition of used lamps, request an industrial waste disposal contractor.
· If you continue to use a lamp after the replacement time, the lamp may break.
· Philips screwdriver is necessary when replacing a lamp unit.
Take care not to slip your hand when using a screwdriver.
Attention
· A lamp unit is an optional part. Contact the dealer.
Replacement lamp unit model No.: ET-LAD12K (single bulb), ET-LAD12KF (4 bulbs)
Rating: 300 W
· Other lamps than specified above cannot be used. Be sure to use the specified lamp.
· Must use the supporting metal fittings after opening the lamp unit cover for safety when replacing the lamp unit in case of the
ceiling installation.

11.2. Timing of Lamp Unit Replacement

The lamp used for the light source has its due life. The life of light source lamp used in the main unit is 2 000 hours. However, it
may happen that the lamp becomes dead (will not light) by the time of 2 000 hours depending on the characteristics of individual
lamps and working conditions (lamps may reduce their life affected by the times of lighting and the intervals between previous
lighting and next lighting). Therefore, it is strongly recommended for the user to keep a spare bulb. If a lamp unit has not been
replaced after 2 000 hours of operation have elapsed, the lamp will turn off automatically. when the operating time for all of the
lamps reaches 2 000 hours or more, the power will turn off automatically approxmately 10 minutes after it is turned on, and the
projector will switch to standby mode.