Programming Custom Schedules
To customize your pump's schedule, the pump must
be stopped. Ensure that the Start/Stop LED is not
illuminated.
The clock must be set before programming a custom
schedule, unless externally controlling the pump
through digital inputs. When controlling the pump
by digital inputs, schedules will be based on the
automation system's clock.
When programming, the LED next to the parameter you
are editing will blink.
"Speed" - Run Speed
"Time" - Start Time
"Duration" - Run Time
TO PROGRAM A CUSTOM SCHEDULE:
1. Press Start/Stop to stop the pump.
2. Press "1". The SPEED 1 LED and the "Speed"
parameter LED will blink while editing. See Figure 9.
3000
Figure 9
3. Use "+" and "-" to adjust the speed in RPM for
SPEED 1.
Note: If operating the pump with external
controls, program SPEED 1 speed to 0 RPM.
4. Press "1". The SPEED 1 start time will display.
The "Time" parameter LED will begin to blink. See
Figure 10.
8 : 00
Figure 10
AM
WHISPERFLO
VS and WHISPERFLO
®
5. Use "+" and "-" to adjust the SPEED 1 start time.
6. Press "1". SPEED 1 duration will display. The
"Duration" parameter LED will begin to blink. See
Figure 11.
2 : 00
Figure 11
7. Use "+" and "-" to adjust the SPEED 1 duration in
hours and minutes.
Note: If operating the pump with external controls,
program SPEED 1 duration to 24 hours.
8. SPEED 1 is now successfully programmed.
Note: Pressing "1" will continue to cycle through
these parameters, but changes are immediately
saved as they are adjusted.
9. Press "2". The SPEED 2 LED and "Speed" parameter
LED will blink while editing.
10. Use "+" and "-" to adjust the speed in RPM for SPEED 2.
11. Press "2". The SPEED 2 duration will display.
Note: SPEEDs 2 and 3 do not have a start time, as
they begin immediately after the previous SPEED
finishes.
12. Use "+" and "-" to adjust the duration of SPEED 2 in
hours and minutes.
13. Repeat steps 9-12 to program SPEED 3 and QUICK
CLEAN.
Note: The duration allowed for SPEED 3 will be
limited to the remaining time in a 24 hour day. Any
time in the 24 hour day not programmed into SPEEDs
1-3, the pump will remain in a stationary state.
[SPEED 1 + SPEED 2 + SPEED 3 < 24 Hours]
14. Press Start/Stop and ensure the Start/Stop LED is
illuminated. The pump is now active and will run the
programmed schedule.
Note: If the pump was stopped using the Start/
Stop button, the pump will not run until the Start/
Stop button is pressed again. If the Start/Stop
LED is illuminated, the pump is on and will run the
programmed schedule.
Note: If you do not want the pump to run during a
specific time of the day, any of the SPEEDs can be
programmed to 0 RPM. This ensures the pump will
not run during the SPEED duration.