Pentair LA STA-RITE Installation And User Manual

Pentair LA STA-RITE Installation And User Manual

Single speed pumps
Hide thumbs Also See for LA STA-RITE:

Advertisement

SINGLE SPEED PUMPS
LA STA-RITE®
LA STA-RITE® HD
ULTRAFLOW®
SUPERFLO®
WHISPERFLO®
PANTERA™
INSTALLATION AND USER'S GUIDE
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS / SAVE THESE INSTRUCTIONS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LA STA-RITE and is the answer not in the manual?

Questions and answers

Summary of Contents for Pentair LA STA-RITE

  • Page 1 SINGLE SPEED PUMPS LA STA-RITE® LA STA-RITE® HD ULTRAFLOW® SUPERFLO® WHISPERFLO® PANTERA™ INSTALLATION AND USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS / SAVE THESE INSTRUCTIONS...
  • Page 2: Important Pump Warning And Safety Instructions

    Warnings and safety instructions for Pentair Aquatic Pentair. Those names and brands may be the trademarks Systems pumps and other related products are available of those parties or others.
  • Page 3: General Warnings

    IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS GENERAL WARNINGS • Never open the inside of the drive motor enclo- the pump by disconnecting the main circuit to the sure. There is a capacitor bank that holds a 230 pump.
  • Page 4 IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN A clearly labeled emergency shut-off WARNING ACCORDANCE WITH THE LATEST CODES, STANDARDS switch for the pump must be in an AND GUIDELINES. easily accessible, obvious place. Make sure users know where it is and how to useit in case of emergency.
  • Page 5: General Installation Information

    IMPORTANT PUMP WARNING AND SAFETY INSTRUCTIONS GENERAL INSTALLATION INFORMATION • All work must be performed by a qualified service • Installing a non-return valve after the pump on the professional, and must conform to all national, state installation will prevent the impeller from unwinding and local codes;...
  • Page 6: Pump Information

    3. Plumbing on the suction side of the pump should be as short as possible. Only to be used to circulate swimming pool water. 4. For most installations Pentair recommends in- stalling a valve on both the pump suction and re- 3.3 - INSTALLATION turn lines so that the pump can be isolated during routine maintenance.
  • Page 7: Start / Operation

    PUMP INFORMATION FITTINGS AND VALVES ELECTRICAL REQUIREMENTS Do not install 90° elbows directly into pump inlet. Install all equipment in accordance with the National Electrical code and all ap- 2. Flooded suction systems should have gate valves plicable local codes and ordinances. installed on suction and discharge pipes for main- Sufficient equipotential bonding (min.
  • Page 8: Electrical Connection

    Single-phase and three-phase wiring diagram: * Below diagram must not take precedence over the electrical scheme on the motor itself. Pentair 1~Supply The electrical power line must be fitted with a short circuit protection device, and a residual current device RCD with high sensitivity (30mA), protected by means of a slow-acting fuse or a magnetothermic switch.
  • Page 9: Troubleshooting

    PUMP INFORMATION 3.6 - SERVICING The pump is designed to operate for many years without servicing. Always disconnect the power supply to the pump before servicing. The replacement of the electrical motor must be done by a professional.Fill pump strainer with water to suction pipe level.

This manual is also suitable for:

Hd la sta-riteUltraflowWhisperfloPanteraSuperflo

Table of Contents