Page 1
WHISPERFLO ® HIGH PERFORMANCE PUMP INSTALLATION AND USER’S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS WHISPERFLO High Performance Pump Installation and User’s Guide ®...
™ and/or registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Water Pool and Spa, Inc.
230 VAC charge even when there is no This guide provides installation and operation instructions for this pump. power to the unit. Consult Pentair with any questions regarding this equipment. • The pump is not submersible. Attention Installer: This guide contains important information about the •...
Page 4
For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches, Timers and Automation Load Center) Warnings and safety instructions for Pentair Aquatic Systems pumps Install all electrical controls at equipment pad, such as and other related products are available at: on/off switches, timers, and control systems, etc.
4. Be sure to install check valves when plumbing in parallel with another pump. This helps prevent reverse 4. For most installations Pentair recommends installing rotation of the impeller and motor. a valve on both the pump suction and return lines so that the pump can be isolated during routine maintenance.
2008 to current 6. Use a strain relief and be sure all electrical connections NEC Standards for Pool Pumps. See Pentair product are clean and tight. catalog for details. 7. Cut the wires to the appropriate length so they do not overlap or touch when connected.
MAINTENANCE DO NOT open the strainer pot if pump fails to prime or if pump has been operating without water in the strainer pot. Pumps operated in these circumstances may experience a build up of vapor pressure and may contain scalding hot water. Opening the pump may cause serious personal injury.
SERVICING Always disconnect power to the pump at the circuit breaker and disconnect the communication cable before servicing the pump. Failure to do so could result in death or serious injury to service people, users or others due to electric shock. Read all servicing instructions before working on the pump.
DO NOT run the pump dry. If the pump is run dry, the mechanical seal will be damaged and the pump will start leaking. If this occurs, the damaged seal must be replaced. ALWAYS maintain proper water level. If the water level falls below the suction port, the pump will draw air through the suction port, losing the prime and causing the pump to run dry, resulting in a damaged seal.
TROUBLESHOOTING Problem Possible Cause Corrective Action Pump failure. Pump will not prime - Air leak, too much air. Check suction piping and valve glands on any suction gate valves. Secure lid on pump strainer pot and be sure lid gasket is in place. Check water level to be sure skimmer is not drawing air.
Pump Performance Curves WhisperFlo High Performance Pump ® WATER FLOW RATE IN US GALLONS PER MINUTE Curve Model WFDS-3, WFDS-24 WFDS-4, WFDS-26 WFDS-6, WFDS-28 WFDS-8, WFDS-30 WFE-2, WF-2, WF-23, WFK-2 WFE-3, WFE-24, WF-3, WF-24, WFK-3, WFDS-3, WFDS-24 WFE-4, WFE-26, WFET-4, WF-4, WF-26, WFK-4, WFDS-4, WFDS-26 WFE-6, WFE-28, WFET-6, WF-6, WF-28, WFK-6, WFDS-6, WFDS-28...
Page 14
WHISPERFLO ® BOMBA DE ALTO RENDIMIENTO GUÍA DE INSTALATIÓN Y DEL USUARIO INSTRUCCIONES IMPORTANTES DE SEGURIDAD LEA Y SIGA TODAS LAS INSTRUCCIONES GUARDE ESTAS INSTRUCCIONES...
Esta guía ofrece las instrucciones de instalación y operación para este producto. cuando la unidad no está conectada a la fuente de alimentación. Consulte a Pentair por cualquier pregunta relacionada con este equipo. • La bomba no es sumergible. • La bomba puede alcanzar caudales de salida elevados; tenga cuidado Atención, instalador: Esta guía contiene información importante sobre...
Page 17
Las advertencias y las instrucciones de seguridad para las bombas y otros coladora de la bomba, la tapa del filtro o los cierres de productos relacionados de Pentair Water Pool and Spa, Inc. se encuentran la válvula. Esta instalación debe otorgar al usuario suficiente espacio para...
3. Utilice una válvula de retención en la línea de Para la mayoría de las instalaciones que Pentair descarga al utilizar esta bomba para cualquier recomienda instalar una válvula en la aspiración de aplicación donde hay altura significativa de la tubería...
DEL CABLE DE ENERGÍA. del eje del motor cuando se detiene. Si está correctamente Pentair ofrece interruptores GFCI que ofrecen la protección conectado, el eje y/o el ventilador coincidirán con la flecha personal adecuada y además cumplen con las normas de NEC de rotación que tiene la bomba.
MANTENIMIENTO NO abra el depósito del filtro si el cebado de la bomba falla o si la bomba ha estado funcionando sin agua en el depósito del filtro. Las bombas que funcionan en estas circunstancias pueden experimentar una acumulación de presión de vapor y pueden contener agua caliente escaldada.
SERVICIO Siempre desconecte la energía hacia la bomba en el interruptor de circuito antes de realizar el servicio a la bomba. Si no se hace esto, las personas que realizan el servicio, los usuarios u otras personas pueden resultar muertas o con heridas de gravedad debido al electrochoque.
NO haga funcionar la bomba en seco. Si hace funcionar la bomba en seco, el sello mecánico se dañará y la bomba comenzará a perder. Si esto ocurre, deberá cambiar el sello dañado. SIEMPRE mantenga el nivel de agua adecuado. Si el nivel de agua cae por debajo del puerto de succión, la bomba extraerá...
LOCALIZADOR DE AVERÍAS Problema Posible causa Medida correctiva Si la bomba falla. La bomba no imprima – demasiado aire. Revise la tubería de succión y las prensastopas en cualquier válvulas de puerta de aspiración. Cierre la tapa en la olla de coladora de bomba y asegúrese que el empaque de tapa está...