and the fan, to reduce the humidity in the room. The
fan speed is not always controlled.
When the mode swing blinds is set, the temperature
-
setting function is not available. Simultaneous
activation of temperature control and horizontal
swing will not be effective. Only high, medium or
low fan speed can be set. The AUTO mode for fan
speed will not be available.
THE ORDER OF OPERATION OF THE AIR CONDITIONER IN
VARIOUS MODES
In cooling or heating mode, the air conditioner
-
maintains the set temperature with an accuracy of
±1 °C. If the set temperature in the cooling mode is
higher than the ambient temperature by more than
1 °C, the air conditioner will operate in ventilation
mode.
If the set temperature in heating mode is lower
-
than the ambient temperature by more than 1 °C,
the air conditioner will operate in ventilation mode.
In AUTO mode, the temperature is not manually
adjusted, the air conditioner automatically
maintains a comfortable temperature of 25±2 °C. If
the temperature is plus 20 °C, the air conditioner
will automatically start working in heating mode. At
a temperature of plus 26 °C, the air conditioner will
turn on in cooling mode.
In DRY mode, the air conditioner maintains the set
-
temperature with an accuracy of ±2 °C. When the air
conditioner is turned on,and the room temperature
is more than 2 °C above the set temperature, then
the air conditioner will operate in cooling mode.
When the temperature reaches below the set
temperature by more than 2 °C, the compressor
and the fan of the outdoor unit stop working, the fan
of the indoor unit rotates at a low speed. In mode
«СОН» (SLEEP) when working for cooling, after
the first hour of operation, the set temperature
automatically increases by 1 °C, after the second by
another 1 °C. Further, the set temperature remains
unchanged.
THE MAIN FUNCTIONS OF REGULATION
To turn ON/OFF the device, press the button "ВКЛ/
ВЫКЛ".
Note:
After the device is turned off, the blinds of the indoor
unit will close automatically.
When you push the button «РЕЖИМ», you can
-
choose the operating mode you need, or select the
preset COOL or HEAT modes.
The "<" and ">" buttons can set the temperature
-
you need. In AUTO mode, the temperature is set
automatically.
By pressing the button «СКОРОСТЬ», you can select
-
the fan speed you need. In TURBO mode, the rotation
speed is set automatically.
By pressing the button "ЖАЛЮЗИ", you can set the
-
desired position of the blinds.
ADDITIONAL CONTROL FEATURES
By pressing the button «СОН», you can turn ON/OFF
-
the night mode.
By pressing the button «ТАЙМЕР» you can set or
-
disable the timer function.
By pressing the button «ДИСПЛЕЙ», you can turn on
-
or off the display backlight on the indoor unit.
By pressing the button «ТУРБО», you can turn ON/
-
OFF intensive mode.
DEFROST FUNCTION
When the temperature in the atmosphere is very low
and the humidity is very high, the radiator of the
outdoor unit can freeze, which can negatively affect
the efficiency of the heating operation. In this case,
automatic defrosting of the external unit is provided.
At the first start after the first hour of operation,
-
the defrost function will be turned on automatically.
The heating operation will be interrupted for 5-15
minutes to perform the defrosting operation.
The fans of the indoor and outdoor unit will be
-
stopped.
During the defrosting process, the outdoor unit
-
may release a certain amount of steam. This is
due to the accelerated defrosting process and is
not a malfunction. After the defrosting process is
completed, the heating operation will be resumed.
REGULATION ORDERS
After connecting the air conditioner to the power
-
supply, press the button "ВКЛ/ВЫКЛ" to turn on the
air conditioner.
34
Need help?
Do you have a question about the NT-65CHB07 and is the answer not in the manual?