Download Print this page

NewTek NT-65CHD07 Instruction Manual

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 31

Quick Links

NT-65CHD07
NT-65CHD09
NT-65CHD12
NT-65CHD18
NT-65CHD24
СПЛИТ - СИСТЕМА КОНДИЦИОНИРОВАНИЯ ВОЗДУХА
АУАНЫ КОНДИЦИОНЕРЛЕУДІҢ СПЛИТ - ЖҮЙЕСІ
SPLIT TYPE AIR CONDITIONER
ՍՊԼԻՏ ՕԴՈՐԱԿՄԱՆ ՀԱՄԱԿԱՐԳ
АБА КОНДИЦИОНЕРДИН СПЛИТ - ТУТУМУ
СЕРИЯ NT
РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ
НҰСҚАУЛЫ ПАЙДАЛАНУШЫ
INSTRUCTION MANUAL
ՕԳՏԱԳՈՐԾՈՂԻ ՁԵՌՆԱՐԿԸ
КОЛДОНУУЧУН ЖЕТЕКЧИЛИГИ

Advertisement

loading
Need help?

Need help?

Do you have a question about the NT-65CHD07 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NewTek NT-65CHD07

  • Page 1 NT-65CHD07 NT-65CHD09 NT-65CHD12 NT-65CHD18 NT-65CHD24 РУКОВОДСТВО ПОЛЬЗОВАТЕЛЯ НҰСҚАУЛЫ ПАЙДАЛАНУШЫ INSTRUCTION MANUAL ՕԳՏԱԳՈՐԾՈՂԻ ՁԵՌՆԱՐԿԸ КОЛДОНУУЧУН ЖЕТЕКЧИЛИГИ СПЛИТ - СИСТЕМА КОНДИЦИОНИРОВАНИЯ ВОЗДУХА АУАНЫ КОНДИЦИОНЕРЛЕУДІҢ СПЛИТ - ЖҮЙЕСІ SPLIT TYPE AIR CONDITIONER ՍՊԼԻՏ ՕԴՈՐԱԿՄԱՆ ՀԱՄԱԿԱՐԳ АБА КОНДИЦИОНЕРДИН СПЛИТ - ТУТУМУ СЕРИЯ NT...
  • Page 2: Назначение Прибора

    Уважаемый покупатель! зетки. Поздравляем Вас с приобретением системы конди- Во время работы прибора не пытайтесь отклю- ционирования воздуха ТМ NEWTEK! чить его, используя автоматический выключа- Пожалуйста, перед началом эксплуатации вни- тель, и не вынимайте вилку из розетки. В резуль- мательно изучите данную инструкцию, которая...
  • Page 3 ОСТОРОЖНО! 2. КОМПЛЕКТНОСТЬ Не устанавливайте прибор под прямыми солнеч- Комплектность внутреннего блока: ными лучами. Внутренний блок – 1 шт. Не блокируйте входное или выходное воздуш- Руководство пользователя – 1 шт. ные отверстия, это снизит охлаждающую или Пульт ДУ – 1 шт. нагревающую...
  • Page 4: Пульт Дистанционного Управления

    3. ОПИСАНИЕ ПРИБОРА ПУЛЬТ ДИСТАНЦИОННОГО УПРАВЛЕНИЯ УСТРОЙСТВО ПРИБОРА 1. Шнур питания 2. Дисплей 3. Передняя панель 4. Воздушный фильтр-сетка 5. Горизонтальные жалюзи 6. Вертикальные жалюзи 7. Кнопка аварийного запуска** 8. Трасса для хладагента* 9. Изоляция* 10. Дренажная трасса* 11. Пульт дистанционного управления 12.
  • Page 5 8. Кнопка «ДИСПЛЕЙ» – подсветка дисплея на 1 2 3 4 5 внутрен нем блоке. 9. Кнопка «ФУНКЦИИ» – активация режимов IFeel, Самоочистка, Тихий, Сон. 10. Кнопка «ЖАЛЮЗИ» – управление направлением воз душного потока за счет изменения положения жалюзи. 11. Кнопка «СКОРОСТЬ» – выбор скорости вращения венти...
  • Page 6 15. Индикатор включения режима «ТАЙМЕР». В режиме AUTO функция ночного режима недо- 16. Настройка температуры. Отображается заданная ступна. температура. Когда установлен режим DRY, в соответствии с ве- 17. Индикатор функции ECO. Отображается при на- личиной О - разницей между температурой в по- жатии...
  • Page 7 ОСНОВНЫЕ ФУНКЦИИ УПРАВЛЕНИЯ ускоренным процессом разморозки и не является Для включения/выключения прибора нажмите неисправностью. После завершения разморозки кнопку "ВКЛ/ВЫКЛ". работа прибора на обогрев будет возобновлена. Примечание: после выключения прибора жалюзи ПОРЯДОК УПРАВЛЕНИЯ внутреннего блока закроются автоматически. После подключения кондиционера к сети электро- питания...
  • Page 8: Техническое Обслуживание

    Примечание: во избежание травм при снятии передней панели Замените батарейки, если ЖК-дисплей пульта ДУ не прикасайтесь к металлическим деталям корпуса; не светится или когда пульт ДУ не может быть ис- при чистке передней панели прибора и пульта пользован для изменения настроек кондиционера. дистанционного...
  • Page 9: Возможные Неисправности И Методы Их Устранения

    В начале сезона подключите прибор к сети; Необходимо выполнить следующие действия: установите батареи в ПДУ. убедитесь, что места забора и выпуска воздуха на внутреннем и наружном блоках не заблокированы; убедитесь в отсутствии ржавчины и коррозии на наружном блоке; убедитесь, что воздушный фильтр очищен; ВОЗМОЖНЫЕ...
  • Page 10 6. МОНТАЖ СПЛИТ - СИСТЕМЫ Наружный блок монтируют на прочный и надеж- Перед монтажом оборудования рекомендуется де- ный фундамент, который не приведет к увеличе- тально ознакомиться с данной инструкцией. нию шума или вибраций. Работы по монтажу должны производиться толь- Для достижения высокой эффективности охлаж- ко...
  • Page 11: Установка Внутреннего Блока

    Теплоизоляционная Большая трубка Внутренний труба блок Шнур питания L max = 20 м <5 м Наружный блок Маленькая труба Дренажный шланг Рис. 5 Рис. 2 УСТАНОВКА МОНТАЖНОЙ ПАНЕЛИ Расположите металлическую монтажную панель внутреннего блока на стене в соответствии с рис. 3. Для...
  • Page 12: Установка Наружного Блока

    Расположите соединительные трубы, кабель, дренажный шланг, как показано на рис. 6, а за- тем подсоедините дренажный шланг к сливному отверстию. Дренажный шланг расположите под наклоном (вниз). Скрепите соединительные трубы, кабели и дренажный шланг вместе виниловой лен- той (рис. 5). Обеспечьте достаточное пространство между...
  • Page 13 Закрепите монтажную раму на стене. Обвязка должна начинаться от нижней части на- Закрепите наружный блок с помощью 4 болтов на ружного блока к внутреннему блоку. монтажных кронштейнах. Рекомендованная толщи- Закрепите ПВХ-ленту липкой лентой, для более на- на стали - не менее 2 мм. дежной...
  • Page 14 (обычно проблема находится в месте подсоединения медных трубок к выходам блоков). Если все нормально, не отключая шланг насоса, полностью открутите клапан, который находится внизу. Внутри системы послышатся звуки — фреон заполняет систему. Теперь быстро открутите шланг вакуумного насоса. Из клапана может выйти неко- торое...
  • Page 15 МОДЕЛЬ 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Электрический кабель Длина, м Кол-во жил кабеля, шт Сечение, мм Материал внешней оплетки резина Межблочный кабель Длина, м Кол-во жил кабеля, шт Сечение, мм Материал внешней оплетки резина ТАБЛИЦА КОДОВ НЕИСПРАВНОСТЕЙ Код ошибки Определение кода ошибки Ошибка...
  • Page 16: Технические Характеристики

    7. ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ МОДЕЛЬ 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Источник питания В/Гц рекомендованный диапазон - 220-240 /~50, допустимый - 198-252 /~50 БТЕ 7500 9200 12000 18000 24000 Производитель- ность Вт 2300 2600 3720 5450 7400 Ном. Охлаждение Вт 1150 1690 2300 мощность...
  • Page 17: Утилизация Прибора

    бора или в случае его неисправности обратитесь в авторизированный сервисный центр ТМ NEWTEK. Адрес центра можно найти на сайте https://newtek.ru/servis. Способы связи с сервисной УСЛОВИЯ ГАРАНТИЙНОГО ОБСЛУЖИВАНИЯ поддержкой: тел: +7 (988) 24-00-178. Генеральный 1. Гарантия действует при соблюдении следующих сервисный центр ООО «Ларина-Сервис», г. Крас- условий...
  • Page 18: Қауіпсіздік Шаралары

    • использование прибора в строгом соответствии дукцией ТМ NEWTEK, людям, домашним животным, с инструкцией по эксплуатации; имуществу потребителя и/или иных третьих лиц • соблюдение правил и требований безопасности. в случае, если это произошло в результате несо- 3. Гарантия не включает в себя периодическое об- блюдения...
  • Page 19 жұмысында күрделі іркілістер орын алуы немесе – Аспап пен ашық отпен жұмыс істейтін ас пап- өрт шығуы мүмкін. тың (газ плитасы және т.б.) бір уақытта жұмыс – Сіздің электр қуат желісіңіз міндетті түрде жерге істеуі кезінде, орынжайды жиі жел детіп тұру тұйықталған...
  • Page 20 – Сплит-жүйелерді тасымалдау, сату бойынша ерек- Сүзгілер: ше шарттар: конди цио нер лердің сыртқы блокта- – Сильвер-ион* бактерияға қарсы сүзгісі - 1 дана рын ТЕК тігінен тұрған күйде тасымалдау керек, – Биосүзгі* - 1 дана ішкі блоктарды тасымалдау кезінде көлденең де, –...
  • Page 21 * Бұл көрсетілгендер кондиционердің әдеттегі 7. "ТАЙМЕР" батырмасы – қосу және өшіру үшін жиынтықтамасымен жеткізілмейді таймерді іске қосу. ** Бұл серияда қолданылмайды 8. "ДИСПЛЕЙ" батырмасы – ішкі блоктағы дисплейдің жарықшасы. ҚАШЫҚТАН БАСҚАРУ ПУЛЬТІ 9. "ФУНКЦИИ" батырмасы – ІFeel, Өзін-өзі тазарту, Тыныш, Ұйқы...
  • Page 22 5. Фаренгейт немесе Цельсий шкаласына ауысу үшін 10. Көлденеңінен тербелуі. Батырманы басқан кезде аспап қосылғаннан кейін 5 с ішінде температу- көрсетіледі "ЖАЛЮЗИ" (опция түрінде). раны көбейту және азайту пернелерін басыңыз 11. IFeel режимінің қосылу индикаторы. және ұстап тұрыңыз. 12. Health режимінің қосылу индикаторы. 13.
  • Page 23 кәдеге жарату алдында одан батареяларды алып кенде, компрессор мен сыртқы блок желдеткіші тастап, кәдеге жарату қажет. жұмысын тоқтатады, ішкі блок желдеткіші төмен жылдамдықпен айналады. "ҰЙҚЫ" режимінде Ескертпе: жұмыстың бірінші сағатынан кейін салқындату AUTO режимінде кондиционер бөлме темпера- кезінде берілген температура автоматты түрде турасы...
  • Page 24 қосылады. Еріту операциясын орындау үшін жы- AAA типті екі сілтілі батареяны салыңыз, олардың лыту операциясы 5-15 минутқа тоқтатылады. көрсетілген бағытқа сәйкес салынғанына көз Ішкі және сыртқы блок желдеткіштері тоқтатылады. жеткізіңіз. Еріту процесінде сыртқы блок белгілі бір мөлшерде Аспапты қосу/өшіру батырмасын басыңыз. бу...
  • Page 25: Техникалық Қызмет Көрсету

    ІШКІ БЛОКТЫҢ АЛДЫҢҒЫ ПАНЕЛІНЕ КҮТІМ ЖАСАУ – ауа сүзгілерін тазартыңыз; Аспапты мұқият күту және уақтылы тазалау оның – ішкі және сыртқы блокты жұмсақ құрғақ қолданылу мерзімін ұзартады және электр энерги- майлықпен сүртіңіз; ясын үнемдейді. – ҚБТ-дан батареяларды алып тастаңыз. Тазалау кезінде төмендегідей ұсыным дарды Маусымның...
  • Page 26 МҮМКІН БОЛАТЫН АҚАУЛЫҚТАР ЖƏНЕ ОЛАРДЫ ЖОЮ ƏДІСТЕРІ Сплит-жүйе іске - Аша электрлік қуат беру розеткасына дұрыс тығылмаған қосылмайды - ҚБТ-дағы батареялардың қуаты таусылған - Қорғаныш іске қосылды - Электр желісі кернеуінің жеткіліксіздігі Ауа салқындамайды - Қоршау және ауа шығу жерлері бұғатталған немесе...
  • Page 27 МОДЕЛІ 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Электр кабелі Ұзындығы, м Кабель тарамдарының саны, дана Қима, мм Сыртқы өру материалы резеңке Блокаралық кабель Ұзындығы, м Кабель тарамдарының саны, дана Қима, мм Сыртқы өру материалы резеңке АҚАУЛЫҚТАР КОДТАРЫ Қателік коды Қателік кодын анықтау Қоршаған...
  • Page 28: Техникалық Сипаттамалар

    7. ТЕХНИКАЛЫҚ СИПАТТАМАЛАР МОДЕЛІ 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Қуат беру көзі В/Гц ұсынылған ауқым - 220-240 /~50, рұқсат етілген ауқым - 198-252 /~50 Салқындату BTU/h 7500 9200 12000 18000 24000 Өнімділігі Вт 2300 2600 3720 5450 7400 Ном. Вт 1150 1690 2300...
  • Page 29 тушы фирмасының өкілінің қолы, әрбір жыртыл- жылы, 4 және 5 белгілер – Өндіріс айы). Аспапқа малы купондағы мөрлер, сатып алушының қолы қызмет көрсету бойынша мәселелер туындағанда болған жағдайда. немесе аспап бұзылса, NEWTEK сауда маркасының Жоғарыда көрсетілген құжаттар ұсынылмаған авторландырылған сервис орталығымен...
  • Page 30: Dear Customer

    4. Кепілдік қолданылмайтын жағдайлар: үшін; тұтынушының және/немесе өзге үшінші механикалық зақым; тұлғалардың еңсерілмейтін күш жағдайларының құрылғының табиғи тозуы; қасақана және/немесе абайсызда әрекеттері пайдалану шарттарын сақтамау немесе иесінің (әрекетсіздігі) үшін жауапты болмайды. қате әрекеттері; 7. Сервистік орталыққа жүгінген кезде бұйымды дұрыс орнату, тасымалдау; қабылдау...
  • Page 31 – Avoid fouling of the power cable plug. Always firmly WARNING! insert the plug into the power socket. A fouled or – Do not expose the appliance to direct sunlight. loosely inserted plug can cause a fire or electric – Do not block the air intakes and outlets as this will shock.
  • Page 32 ATTENTION! 3. DESCRIPTION OF THE DEVICE – This air conditioning system can only be used for STRUCTURE OF DEVICE domestic purposes! – Immediately disconnect the appliance from power supply in case of any abnormality in its operation (smell of burning, foreign noise, etc.). –...
  • Page 33 REMOTE CONTROL UNIT Quiet and Sleep modes. 10. «ЖАЛЮЗИ» - Flap Control button. 11. «СКОРОСТЬ» – selects the fan rotation speed: 12. «РЕЖИМ» – selects the operating mode: Note: 1. The overview of the RC unit provided above is for reference purposes only;...
  • Page 34 1 2 3 4 5 16. Temperature setting. The set temperature is displayed. 17. ECO function activation indicator. Displayed when the ECO button is pressed. 18. “Children” function activation indicator. 4. CONTROLLING THE APPLIANCE INSTRUCTIONS FOR USING THE REMOTE CONTROL The remote control uses two AAA alkaline batteries.
  • Page 35 and the fan, to reduce the humidity in the room. The Note: fan speed is not always controlled. After the device is turned off, the blinds of the indoor When the mode swing blinds is set, the temperature unit will close automatically. setting function is not available.
  • Page 36: Air Conditioner Maintenance

    With the button «РЕЖИМ» select the mode COOL or AIR CONDITIONING CONTROL WITHOUT REMOTE CONTROL НЕАТ. Use the "<" and ">" buttons to set the temperature in the range 16-32 °C. In AUTO mode, the temperature is set automatically and is not set from the remote control. With the button «СКОРОСТЬ»...
  • Page 37: Air Filter Cleaning

    – Do not use alcohol-containing liquids, gasoline, oils or polishers to clean the unit. – Do not apply too much force to the front panel as this may cause it to fall off. – Do not use abrasive cleaners or metallic sponges to avoid damage of the appliance’s surface.
  • Page 38 POSSIBLE MALFUNCTIONS AND METHODS FOR THEIR ELIMINATION The AC will not turn on – the plug is not firmly inserted in the power socket – RC batteries are depleted – overload safety has been tripped – insufficient power system voltage The air is not cooled/heated –...
  • Page 39 Model 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Electrical cable Length, m Number of cable cores, pcs Section, mm Outer braid material rubber Interconnect cable Length, m Number of cable cores, pcs Section, mm Outer braid material rubber TABLE OF FAULT CODES Error code Problem Ambient temperature sensor error (indoor unit)
  • Page 40: Specifications

    7. SPECIFICATIONS MODEL 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Power supply V/Hz recommended range - 220-240 /~50, allowable range - 198-252 /~50 Cooling BTU/h 7500 9200 12000 18000 24000 Output 2300 2600 3720 5450 7400 Nominal power 1150 1690 2300 rating Nominal current 2.90 3.71...
  • Page 41 – the appliance is used in strict accordance with the should arise, or if the appliance has malfunctions, present manual; apply to the NEWTEK TM Authorized Service Center. – the safety rules and requirements are observed. The address of the service center can be found on 3.
  • Page 42 ինչպես նաև սարքի վաղաժամ փչացումը possible damage, directly or indirectly inflicted կանխելու համար անհրաժեշտ է խստորեն by NEWTEK brand products on people, domestic պահպանել ստորև նշված պայմանները՝ animals, the consumer’s or third persons’ property Օ գ տ ա գ ո ր ծ ե ք հ ա մ ա պ ա տ ա ս խ ա ն...
  • Page 43 Մի օգտագործեք երկարացման լարեր Արգելվում է տեղադրել այս սարքը բարձր – – և մի միացրեք սարքը վարդակին, որին խոնավություն ունեցող տարածքներում, միացված են էլեկտրաէներգիայի այլ ինչպես նաև այն վայրերում, որտեղ սպառողներ: ագրեսիվ քիմիական նյութերի գոլորշիներ Խնդիրներ առաջանալու դեպքում նախ են արտանետվում: –...
  • Page 44 Դրենաժային միակցիչ - 1 հատ * Ձեր օդորակիչի բլոկների արտաքին – տեսքը կարող է տարբերվել հրահանգների Ամրացնող օղակ - 1 հատ – սխեմատիկ պատկերներից: * Այս տարրերը չեն մատակարարվում զտիչներ (ֆիլտրեր) օդորակիչի ստանդարտ կոմպլեկտացի- - Հակաբակտերիալ ֆիլտր այում: - Սիլվեր - իոն* - 1 հատ ** Չի...
  • Page 45 «TURBO» կոճակ՝ աշխատանքի 4. Սեղմեք «ФУНКЦИИ» կոճակը, որպեսզի ինտենսիվ ռեժիմի ակտիվացում: վերադառնաք վերջին սահմանված գործառույթին: Ընտրելու համար 5. «ECO» կոճակ՝ էներգախնայողության օգտագործեք < / >: Սահմանվելիք ռեժիմի ակտիվացում: ֆունկցիայի պատկերակը 10 վայրկյան «ДЕТИ» («Երեխաներ») կոճակ՝ կառկայծի: Ընտրելու համար պահեք երեխաների համար...
  • Page 46 on ռեժիմի դեպքում։ սուր առարկա (օրինակ՝ գրիչի ծայրը) ՝ վերակայման կոճակը («Сброс») սեղմելու 5. Տուրբոռեժիմի սիմվոլ։ Հայտնվում համար: է, երբ սառեցման կամ տաքացման - Հեռակառավարման վահանակի ռեժիմում սեղմում եք «ТУРБО» կոճակը, գործարկման արդյունավետ ընդ որում օդի արագության նշանը հեռավորությունը մոտ 8 մետր է: առկայծում...
  • Page 47 սենյակի խոնավությունը։ Այս դեպքում հետո, սահմանված ջերմաստիճանը օդափոխիչի պտտման արագությունը ինքնաբերաբար ավելանում է 1 °C- ով, միշտ չէ, որ վերահսկվում է: երկրորդից հետո՝ ևս 1 °C- ով: Այնուհետև, - Երբ ռեժիմը սահմանված է, սահմանված ջերմաստիճանը մնում է ջերմաստիճանի կարգավորման անփոփոխ: գործառույթը...
  • Page 48 բացասաբար անդրադառնալ ջեռուցման ՀԵՌԱԿԱՌԱՎԱՐՄԱՆ ՎԱՀԱՆԱԿԻ աշխատանքի արդյունավետության վրա: ՄԱՐՏԿՈՑՆԵՐԻ ՓՈԽԱՐԻՆՈՒՄԸ Այս դեպքում նախատեսված է արտաքին միավորի ավտոմատ հալեցում: - Աշխատանքի առաջին ժամից հետո առաջին անգամ գործարկելիս հալեցման գործառույթը ինքնաբերաբար կակտիվանա: Ջեռուցման գործողությունը կդադարեցվի 5-15 րոպեյով հալեցման աշխատանքն իրականացնելու համար: - Ներքին և...
  • Page 49 ՕԴԱՈՐԱԿԻՉԻ ԿԱՌԱՎԱՐՈՒՄՆ ԱՌԱՆՑ ս ա ր ք ի դ ի մ ա յ ի ն վ ա հ ա ն ա կ ը և – ՀԵՌԱԿԱՌԱՎԱՐՄԱՆ ՎԱՀԱՆԱԿԻ հ ե ռ ա կ ա ռ ա վ ա ր մ ա ն վ ա հ ա ն ա կ ը ՕԳՆՈՒԹՅԱՆ...
  • Page 50 համոզվեք, որ ներքին և արտաքին բլոկերի – օդի ընդունման ու արտանետման տեղերը արգելափակված չեն, հ ա մ ո զ վ ե ք , ո ր ա ր տ ա ք ի ն բ լ ո կ ը – ժանգոտված և քայքայված չէ, համոզվեք, որ...
  • Page 51 Մոդել 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Էլեկտրական մալուխ Երկարություն, մ Միավորների քան-ապրել մալուխի, կտոր Բաժին, մմ Արտաքին հյուսքի նյութ ռետինե Միջբանկային մալուխ Երկարություն, մ Միավորների քան-ապրել մալուխի, կտոր Բաժին, մմ Արտաքին հյուսքի նյութ ռետինե ԱՆՍԱՐՔՈՒԹՅԱՆ ԿՈԴԵՐ Սխալի կոդ Խնդիր Շրջակա օդի ջերմաստիճանի տվիչի սխալ (ներքին բլոկ) Ներքին...
  • Page 52 7. ՏԵԽՆԻԿԱԿԱՆ ԲՆՈՒԹԱԳԻՐԸ ՄՈԴԵԼ 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Սնուցման աղբյուրը Վ/Հց Առաջարկվող միջակայքը - 220-240 /~50, թույլատրելի միջակայքը - 198-252 /~50 Սառեցում BTU/h 7500 9200 12000 18000 24000 Արդյունավետությունը Վտ 2300 2600 3720 5450 7400 Նոմինալ հզորությունը Վտ 1150 1690 2300 Նոմինալ...
  • Page 53 Ա ր տ ա դ ր ո ղ ը ի ր ա վ ա ս ո ւ է մ ե ր ժ ե լ Սարքի սպասարկման ժամանակ որևէ երաշխիքային սպասարկումը վերը նշված հարցի ծագման կամ դրա անսարքության փաստաթղթերը չներկայացնելու դեպքում, դեպքում դիմեք TM NEWTEK-ի լիազորված կամ եթե դրանցում նշված տեղեկությունը սպասարկման կենտրոն: Կենտրոնի հասցեն թերի, անհասկանալի կամ հակասական է: կարելի է գտնել https://newtek.ru/servis 2.
  • Page 54 կրում մարդկանց, ընտանի կենդանիներին, алыматка ылайык, ылайыктуу электр булагын սպառողի կամ երրորդ անձանց գույքին TM колдонуңуз, антпесе шайман олутту иштен чыгып «NEWTEK»-ի ապրանքի կողմից ուղղակիորեն же өрт чыгышы мүмкүн. կամ անուղղակիորեն հասցված որևէ վնասի համար, եթե դա տեղի է ունեցել ապրանքի...
  • Page 55 ген сайгыч өрткө же электр тогуна урунууга алып ЭТИЯТ БОЛУҢУЗ! келиши мүмкүн. – Шайманды түз күндүн нурлардын астына – Эгер сиз шайманды көпкө чейин колдонбосоңуз, орнотпоңуз. коопсуздук үчүн, розеткадан сууруп салыңыз. – Аба кирүүчү же чыгуучу тешиктерди жаппаңыз, – Шайман иштеп жатканда, аны автоматтык бул...
  • Page 56 Алыстан башкаруу пульт - 1 д. 6. Тик жалюзи "ААА" тибиндеги камсыздоо элементи* - 2 д. 7. Өзгөчө кырдаалда ишке киргизүү баскычы** 8. Муздатуучу зат үчүн жол* Тышкы блоктун толуктугу: 9. Жылуулоо* Тышкы блок - 1 д. 10. Дренаждык жол* Толкундуу...
  • Page 57 АЛЫСТАН БАШКАРУУ ПУЛЬТТУН БАСКЫЧТАРЫНЫН 4. Акыркы коюлган функцияга кайтуу үчүн "ФУНК- МААНИСИ ЦИЯ" баскычын басыңыз. Тандоо үчүн < / > колдонуңуз. Орнотула турган функциянын бел- 1. Алыстан башкаруу пульттун дисплейи. гиси 10 секундага күйөт. Тандоо үчүн "ФУНКЦИЯ" 2. Күйгүзүү/Өчүрүү баскычы. баскычын...
  • Page 58 8. Абанын ылдамдыгы: көйгөйлөр пайда болуп жатса, сураныч, түзмөктү өчүрүңүз, сайгычты розеткадан чыгарыңыз, андан кийин аны туташтырыңыз жана бир нече убакыт- тан кийин күйгүзүп коюңуз. Алыстан башкаруу пультту жерге түшүрбөңүз. Алыстан башкаруу пультту күн нурунун тийип турган аймакта же кызарткыч мештин жанында койбоңуз.
  • Page 59 төмөн болсо - кондиционер желдетүү режимде "ТАЙМЕР" баскычын басуу менен таймердин иштейт. AUTO режиминде температура кол менен функциясын орнотууга же өчүрүүгө болот. жөнгө салынбайт, кондиционер автоматтык түрдө "ДИСПЛЕЙ" баскычын басуу менен ички блокто- ыңгайлуу 25±2 °С температураны колдойт. Эгер гу дисплейдин арткы жарыгын куйгүзүүгө же температура...
  • Page 60 АЛЫСТАН БАШКАРУУ ПУЛЬТТУН ИЧИНДЕГИ БАТАРЕЙ- Энергетика сиз алыстан башкаруу пультту жоготуп КАЛАРДЫ АЛМАШТЫРУУ койсоңуз же ал бузулуп калса, кийинки кадамдарды жасаңыз: 1. Эгер кондиционер иштебей жатса. Эгер сиз кон- диционерди ишке киргизгиңиз келсе, ички блок- тун авариялык баштоо баскычын басыңыз (муну жасоодон...
  • Page 61 тазалоо үчүн абразивдүү каражаттарды же болот- Сезондун башында тон жасалган губканы колдонбоңуз. Төмөнкү иш - чараларды жүргүзүш керек: Суунун температурасы 45 °С дан ашпашы ке- – ички жана тышкы блоктордун аба соруучу жана рек. Бул деформациянын же пластиктин түсүнө чыгуучу жерлери тосулуп калбагандыгына көз өзгөрүшүнө...
  • Page 62 МҮМКҮН БОЛГОН БУЗУУЛАР ЖАНА АЛАРДЫ ЖОЮУ ЫКМАЛАРЫ Сплит-тутуму ишке кирбей – Сайгычы электр розеткага бекем кирген жок жатат – Пультта батарейкалар бошотулду – Коргоо иштеп кетти – Электр тармагындагы чыңалуу жетишсиз Аба муздабай жатат же – Аба соруучу жана чыгуучу жерлер кулпуланган ысыбай...
  • Page 63 7. ТЕХНИКАЛЫК МҮНӨЗДӨМӨЛӨР МОДЕЛЬ 65CHD07 65CHD09 65CHD12 65CHD18 65CHD24 Камсыздоо булагы В/Гц сунуш кылынган диапазон - 220-240 /~50, уруксат берилген - 198-252 /~50 Муздатуу BTU/h 7500 9200 12000 18000 24000 Өндүрүү Вт 2300 2600 3720 5450 7400 Номиналдуу Вт 1150 1690 2300 күчтүүлүгү...
  • Page 64 5 белгиси – өндүрүш айы). Шайманды тейлөө боюнча шаймандын колдонуу көрсөтмөсүнө ылайык так • суроолор пайда болгондо же шайман бузулган учурда, колдонуу; TM NEWTEK ыйгарым укуктуу тейлөө борборуна эрежелерди жана коопсуздук талаптарын сактоо. • кайрылыңыз. Дарегин https://newtek.ru/servis Кепилдик мезгил-мезгили менен техникалык тейлөө, сайтынан...
  • Page 65 мыйзамына ылайык укуктарын эч кандай чектебейт. Өндүрүүчү TM NEWTEK тин өндүрүшү адамдарга, ү й ж а н ы б а рл а р ы н а , ке р е к т ү ү мү л к ү н ө...

This manual is also suitable for:

Nt seriesNt-65chd09Nt-65chd12Nt-65chd18Nt-65chd24