ELECTRIC STARTING SYSTEM
EAM30280

STARTING CIRCUIT CUT-OFF SYSTEM OPERATION

If the meter light comes on, the starter motor can only operate if at least one of the following conditions
is met:
• The transmission is in neutral (the neutral circuit of the gear position switch is closed).
• The clutch lever is pulled to the handlebar (the clutch switch is closed).
The starting circuit cut-off relay prevents the starter motor from operating when neither of these condi-
tions has been met. In this instance, the starting circuit cut-off relay is open so current cannot reach the
starter motor. When at least one of the above conditions has been met the starting circuit cut-off relay
is closed and the engine can be started by pressing the start switch.