ABB Smart Original Instructions Manual page 8

Safety and motion analyser tool
Table of Contents

Advertisement

Analogue sensors
Analogue sensors are connected to connector 6 and 4 (input I9 and I10). Pin 5 is the current loop's plus connector
and pin 4 is the current loop's minus connector. Pin 2 is not used.
Power supply
The power supply SM6 is connected to connector 2 with 24 VDC on pin 1 and 0VDC on pin 3. Pin 2, 4 and 5 are
not used.
Connection examples
In signal to I3 from machine system
Smart Logger
I3 (pin-5 on connector 5)
0 VDC (pin-3 on connector 5)
Out signal from Q0 to machine system
Smart Logger
24 VDC (pin-1 on connector 7)
Q0 (pin-2 on connector 7)
Connection of two-wire analogue sensor to I9
Smart Logger
24 VDC (pin-1 on connector 6)
+ (pin-5 on connector 6)
- (pin-4 on connector 6)
0 VDC (pin-3 on connector 6)
Pulse sensor
To measure motion, speed and position a pulse sensor (SM5/SM7) is connected to Smart Logger. The pulse
sensors have a resolution of 0.1 mm, i.e. they send 10 pulses/mm. Based on incoming pulses Smart Logger
calculates at which position the sensors are and at what speed they move.
2TLC172188M0201, rev. H
2012-01-03
Machine system
5-24 VDC
0 VDC
Machine system
Analogue sensor
+ (Supply)
- (Common)
8