Option 2 (Alternate Method)
Approved aluminum or copper tubing:
@
Lengths under 20 ft. (6.1 m) can use 3/8" approved tubing
(if codes and gas supplier permit).
@
if you are using Natural Gas, do not use copper tubing.
@
3/8" flare x 3/8" NPT adapter fitting between dryer pipe and
3/8" approved tubing.
@
Lengths over 20 ft. (6.1 m) should use larger tubing and a
different size adapter fitting.
@
if your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft. (6.1 m), use larger pipe.
NOTE: Pipe joint compounds that resist the action of LP
gas must be used. Do not use TEFLON® tape.
Dryer gas pipe
@
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
A. 3/8" NPT dryer pipe
Burner input requirements
Elevations up to 10,000 ft. (3,048 m):
@
The design of this dryer is certified by CSA International for
use at altitudes up to 10,000 ft. (8,048 m), above sea level at
the B.T.U. rating indicated on the model/serial number plate.
Burner input adjustments are not required when the dryer is
operated up to this elevation.
Elevations above 10,000 ft. (3,048 m):
@
When installed above 10,000 ft. (8,048 m) a 4% reduction
of the burner B.T.U. rating shown on the model/serial
number plate is required for each 1,000 ft. G05 m)
increase in elevation.
Gas supply pressure testing
@
The dryer must be disconnected from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
T®TEFLON
is a registered trademark of E.1. Du Pont De Nemours and Company.
VENTING
Venting Requirements
Gh
é
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building. Only rigid or flexible metal vent shall be used for
exhausting.
4t
(102 mm)
4" (102 mm) heavy metal exhaust vent
@
Only a4" (102 mm) heavy metal exhaust vent and clamps
may be used.
@
Donotuse plastic or metal foil vent.
Rigid metal vent:
@
Recommended for best drying performance and to avoid
crushing and kinking.
Flexible metal vent: (Acceptable only if accessible to clean)
@
Must be fully extended and supported in final dryer location.
@
Remove excess to avoid sagging and kinking that may result
in reduced airflow and poor performance.
@
Donot install in enclosed walls, ceilings, or floors.
@
The total length should not exceed 7 °/s ft. (2.4 m).
NOTE: If using an existing vent system, clean lint from entire
length of the system and make sure exhaust hood is not plugged
with lint. Replace plastic or metal foil vents with rigid metal or
flexible metal vents. Review Vent System Chart and if necessary,
modify existing vent system to achieve best drying performance.