Alternate installations for close clearances
Venting systems come in many varieties. Select the type best
for your installation. Two close-clearance installations are shown.
Refer to the manufacturer's instructions.
Periscope installation
NOTE: The following kits for close clearance alternate
installations are available for purchase.
Venting Kits
For more information, call 1-800-469-4663, or visit us
at www.sears.com.
In Canada, call
1-800-469-4663 or visit us at www.sears.ca.
Part Number
Descriptions
Special provisions for mobile home installations:
The exhaust vent must be securely fastened to a noncombustible
portion of the mobile home structure and must not terminate
beneath the mobile home. Terminate the exhaust vent outside.
"|
\
@
Select route that will provide straightest and most direct
path outdoors.
@
Plan installation to use fewest number of elbows and turns.
@
When using elbows or making turns, allow as much room
as possible.
@
Bend vent gradually to avoid kinking.
@
Use as few 90° turns as possible.
Determine vent path:
Determine vent length and elbows needed for best
drying performance:
@
Use following Vent System Chart to determine type of vent
material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified
in Vent System Chart. Exhaust systems longer than those
specified will:
@
Shorten life of dryer.
8171587RP
0-5" Metal vent periscope
@
Reduce performance, resulting in longer drying times
4396037RP
0"-18" Metal vent periscope
and increased energy usage.
439601 1RP
18" - 29" Metal vent periscope
The Vent System Chart provides venting requirements that
4396014
29" - 50" Metal vent periscope
will help achieve best drying performance.
4392892
In-Wall metal DuraVent™
Periscope
(~
4396028
Sure Connect™ venting kit
Vent
System
Chart
(over-the-top installation)
Number of
Type
Box/louvered
Angled
A396009RP
5' Universal connect vent, flexible dryer venting
90° turns or
of vent
hoods
hoods
4396010RP
6' SecureConnect™ vent, flexible dryer venting
elbows
4396013RB
Dryer vent installer's kit
0
Rigid metal | 64 ft. (20 m)
58 ft. (17.7 m)
4396033RP
5' flexible dryer venting with clamps
4396727RP
8' flexible dryer venting with clamps
1
Rigid metal | 54 ft. (16.5 m) | 48 ft. (14.6 m)
4396004
Dryer offset elbow
4396005
Wall offset elbow
2
Rigid metal | 44 ft. (13.4 m) | 38 ft. (11.6 m)
4396006RW
DuraSafe™ close elbow
4396007RW
Through-the-wall vent cap
3
Rigid metal | 35 ft. (10.7 m) | 29 ft. (8.8 m)
4396008RP
4" steel dryer venting clamps - 2 pack
4
Rigid metal | 27 ft. (8.2 m)
21 ft. (6.4 m)
8212662
Flush mounting louvered vent hood 4"
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add
one 90° turn to the chart.