  • ENGLISH, page 14
Clamp locking ring-nut
S
Safety bellows
T
Holding screws for ring R
U
Screw to adjust stud bolt protrusion
V
Holding nut
W
Stud bolt gripping clamp
X
Screw
Y
Spacer
Z
5.2.1

Preparing the gun

Always use high-quality studs with contact point start-up for capacitor discharge welding, which comply with standards
and are made of a metal compatible with the welding to be done.
Having selected the stud bolt to be welded for type, diameter, length and material, use and adjust the gripping clamp
according to the corresponding diameter.
Insert the stud bolt in the clamp X so that it is fi rmly held in place by the four springs.
Adjust the protrusion of the stud bolt from the front of the clamp to 1 ÷ 1.5 mm using the screw V, then tighten with
the nut W (fi gure 2).
Insert the clamp X into the chuck of the gun (fi g. 2), press until you feel it rest all the way down, and tighten the nut S
using the 17-mm hexagon wrench provided.