Heating [All Indoor Units]; Heating Capacity With Pumy-P100-140Yhmc-C/Vhmc-S - Mitsubishi Electric CITY MULTI PEFY-P22VMS-E-S Data Book

Table of Contents

Advertisement

6. Heating [All indoor units]

6-1. Heating capacity with PUMY-P100-140YHMC-C/VHMC-S

6. Heating [All indoor units]
All Indoor units
Model
Outdoor
size
air temp.
15°C D.B.
(Rated kW)
°C W.B.
SHC
-15.0
1.3
-10.0
1.4
-5.0
1.6
0.0
1.8
2.5
1.9
15
(1.9)
6.0
1.9
7.5
2.1
10.0
2.1
12.5
2.2
15.5
2.3
-15.0
1.8
-10.0
1.9
-5.0
2.1
0.0
2.4
20
2.5
2.5
(2.5)
6.0
2.6
7.5
2.7
10.0
2.8
12.5
3.0
15.5
3.1
-15.0
2.0
-10.0
2.1
-5.0
2.4
0.0
2.6
2.5
2.8
22
(2.8)
6.0
2.9
7.5
3.0
10.0
3.2
12.5
3.3
15.5
3.4
-15.0
2.2
-10.0
2.4
-5.0
2.7
0.0
3.0
25
2.5
3.2
(3.2)
6.0
3.3
7.5
3.5
10.0
3.6
12.5
3.8
15.5
3.9
-15.0
2.5
-10.0
2.7
-5.0
3.1
0.0
3.4
2.5
3.6
28
(3.6)
6.0
3.7
7.5
3.9
10.0
4.1
12.5
4.2
15.5
4.4
-15.0
2.8
-10.0
3.0
-5.0
3.4
0.0
3.8
32
2.5
4.0
(4.0)
6.0
4.1
7.5
4.3
10.0
4.5
12.5
4.7
15.5
4.9
-15.0
3.2
-10.0
3.4
-5.0
3.8
0.0
4.2
2.5
4.5
36
(4.5)
6.0
4.6
7.5
4.9
10.0
5.1
12.5
5.3
15.5
5.5
SHC:Sensible Heat Capacity(kW)
Indoor air temp.
20°C D.B.
25°C D.B.
27°C D.B.
SHC
SHC
SHC
1.3
1.2
1.2
1.4
1.3
1.3
1.6
1.5
1.5
1.7
1.7
1.7
1.8
1.8
1.7
1.9
1.9
1.8
2.0
1.9
1.8
2.1
1.9
1.8
2.2
1.9
1.8
2.2
1.9
1.8
1.7
1.6
1.6
1.8
1.8
1.8
2.1
2.0
2.0
2.3
2.2
2.2
2.4
2.3
2.3
2.5
2.5
2.4
2.7
2.5
2.4
2.8
2.5
2.4
2.9
2.5
2.4
2.9
2.5
2.4
1.9
1.8
1.8
2.0
2.0
2.0
2.3
2.2
2.2
2.6
2.5
2.4
2.7
2.6
2.6
2.8
2.8
2.7
3.0
2.8
2.7
3.1
2.8
2.7
3.2
2.8
2.7
3.2
2.8
2.7
2.1
2.1
2.0
2.3
2.3
2.2
2.7
2.5
2.5
2.9
2.8
2.8
3.1
3.0
2.9
3.2
3.2
3.1
3.4
3.2
3.1
3.5
3.2
3.1
3.7
3.2
3.1
3.7
3.2
3.1
2.4
2.3
2.3
2.6
2.6
2.5
3.0
2.8
2.8
3.3
3.2
3.1
3.5
3.3
3.3
3.6
3.6
3.5
3.8
3.6
3.5
4.0
3.6
3.5
4.1
3.6
3.5
4.1
3.6
3.5
2.7
2.6
2.6
2.9
2.8
2.8
3.3
3.2
3.1
3.7
3.5
3.5
3.8
3.7
3.7
4.0
4.0
3.9
4.2
4.0
3.9
4.4
4.0
3.9
4.6
4.0
3.9
4.6
4.0
3.9
3.0
2.9
2.9
3.3
3.2
3.2
3.7
3.6
3.5
4.1
4.0
3.9
4.3
4.2
4.1
4.5
4.5
4.4
4.8
4.5
4.4
5.0
4.5
4.4
5.2
4.5
4.4
5.2
4.5
4.4
kcal/h=kW x 860 , BTU/h = kW x 3,412
INDOOR UNITS
All Indoor units
Model
Outdoor
size
air temp.
15°C D.B.
(Rated kW)
°C W.B.
SHC
-15.0
3.5
-10.0
3.8
-5.0
4.3
0.0
4.7
2.5
5.0
40
(5.0)
6.0
5.1
7.5
5.4
10.0
5.7
12.5
5.9
15.5
6.2
-15.0
3.9
-10.0
4.2
-5.0
4.8
0.0
5.3
45
2.5
5.5
(5.6)
6.0
5.7
7.5
6.0
10.0
6.3
12.5
6.6
15.5
6.9
-15.0
4.4
-10.0
4.7
-5.0
5.4
0.0
5.9
2.5
6.2
50
(6.3)
6.0
6.4
7.5
6.8
10.0
7.1
12.5
7.4
15.5
7.7
-15.0
4.9
-10.0
5.3
-5.0
6.0
0.0
6.6
56
2.5
6.9
(7.0)
6.0
7.1
7.5
7.6
10.0
7.9
12.5
8.3
15.5
8.6
-15.0
5.6
-10.0
6.0
-5.0
6.8
0.0
7.5
2.5
7.9
63
(8.0)
6.0
8.2
7.5
8.6
10.0
9.0
12.5
9.4
15.5
9.8
-15.0
6.3
-10.0
6.8
-5.0
7.7
0.0
8.5
71
2.5
8.9
(9.0)
6.0
9.2
7.5
9.7
10.0
10.2
12.5
10.6
15.5
11.1
-15.0
7.0
-10.0
7.5
-5.0
8.5
0.0
9.4
2.5
9.9
80
(10.0)
6.0
10.2
7.5
10.8
10.0
11.3
12.5
11.8
15.5
12.3
C7-R Rev.
SHC:Sensible Heat Capacity(kW)
Indoor air temp.
20°C D.B.
25°C D.B.
27°C D.B.
SHC
SHC
SHC
3.4
3.3
3.2
3.7
3.6
3.5
4.2
4.0
3.9
4.6
4.4
4.4
4.8
4.7
4.6
5.0
5.0
4.9
5.3
5.0
4.9
5.5
5.0
4.9
5.8
5.0
4.9
5.8
5.0
4.9
3.8
3.6
3.6
4.1
4.0
3.9
4.6
4.4
4.4
5.2
4.9
4.9
5.4
5.2
5.2
5.6
5.5
5.4
5.9
5.5
5.4
6.2
5.5
5.4
6.4
5.5
5.4
6.4
5.5
5.4
4.2
4.1
4.0
4.6
4.5
4.4
5.2
5.0
4.9
5.8
5.5
5.5
6.0
5.9
5.8
6.3
6.2
6.1
6.7
6.2
6.1
6.9
6.2
6.1
7.2
6.2
6.1
7.2
6.2
6.1
4.7
4.6
4.5
5.1
5.0
4.9
5.8
5.5
5.5
6.4
6.2
6.1
6.7
6.5
6.4
7.0
6.9
6.8
7.4
6.9
6.8
7.7
6.9
6.8
8.1
6.9
6.8
8.1
6.9
6.8
5.4
5.2
5.1
5.8
5.7
5.6
6.6
6.3
6.2
7.4
7.0
7.0
7.7
7.4
7.4
8.0
7.9
7.8
8.5
7.9
7.8
8.8
7.9
7.8
9.2
7.9
7.8
9.2
7.9
7.8
6.0
5.9
5.8
6.6
6.4
6.3
7.5
7.1
7.0
8.3
7.9
7.8
8.6
8.4
8.3
9.0
8.9
8.7
9.5
8.9
8.7
9.9
8.9
8.7
10.4
8.9
8.7
10.4
8.9
8.7
6.7
6.5
6.4
7.3
7.1
7.0
8.3
7.9
7.8
9.2
8.8
8.7
9.6
9.3
9.2
10.0
9.9
9.7
10.6
9.9
9.7
11.0
9.9
9.7
11.5
9.9
9.7
11.5
9.9
9.7
kcal/h=kW x 860 , BTU/h = kW x 3,412
1 - 169

Advertisement

Table of Contents
loading

Table of Contents