6. Heating [All indoor units]
6-1. Heating capacity with PUMY-P100-140YHMC-C/VHMC-S
6. Heating [All indoor units]
All Indoor units
Model
Outdoor
size
air temp.
15°C D.B.
(Rated kW)
°C W.B.
SHC
-15.0
1.3
-10.0
1.4
-5.0
1.6
0.0
1.8
2.5
1.9
15
(1.9)
6.0
1.9
7.5
2.1
10.0
2.1
12.5
2.2
15.5
2.3
-15.0
1.8
-10.0
1.9
-5.0
2.1
0.0
2.4
20
2.5
2.5
(2.5)
6.0
2.6
7.5
2.7
10.0
2.8
12.5
3.0
15.5
3.1
-15.0
2.0
-10.0
2.1
-5.0
2.4
0.0
2.6
2.5
2.8
22
(2.8)
6.0
2.9
7.5
3.0
10.0
3.2
12.5
3.3
15.5
3.4
-15.0
2.2
-10.0
2.4
-5.0
2.7
0.0
3.0
25
2.5
3.2
(3.2)
6.0
3.3
7.5
3.5
10.0
3.6
12.5
3.8
15.5
3.9
-15.0
2.5
-10.0
2.7
-5.0
3.1
0.0
3.4
2.5
3.6
28
(3.6)
6.0
3.7
7.5
3.9
10.0
4.1
12.5
4.2
15.5
4.4
-15.0
2.8
-10.0
3.0
-5.0
3.4
0.0
3.8
32
2.5
4.0
(4.0)
6.0
4.1
7.5
4.3
10.0
4.5
12.5
4.7
15.5
4.9
-15.0
3.2
-10.0
3.4
-5.0
3.8
0.0
4.2
2.5
4.5
36
(4.5)
6.0
4.6
7.5
4.9
10.0
5.1
12.5
5.3
15.5
5.5
SHC:Sensible Heat Capacity(kW)
Indoor air temp.
20°C D.B.
25°C D.B.
27°C D.B.
SHC
SHC
SHC
1.3
1.2
1.2
1.4
1.3
1.3
1.6
1.5
1.5
1.7
1.7
1.7
1.8
1.8
1.7
1.9
1.9
1.8
2.0
1.9
1.8
2.1
1.9
1.8
2.2
1.9
1.8
2.2
1.9
1.8
1.7
1.6
1.6
1.8
1.8
1.8
2.1
2.0
2.0
2.3
2.2
2.2
2.4
2.3
2.3
2.5
2.5
2.4
2.7
2.5
2.4
2.8
2.5
2.4
2.9
2.5
2.4
2.9
2.5
2.4
1.9
1.8
1.8
2.0
2.0
2.0
2.3
2.2
2.2
2.6
2.5
2.4
2.7
2.6
2.6
2.8
2.8
2.7
3.0
2.8
2.7
3.1
2.8
2.7
3.2
2.8
2.7
3.2
2.8
2.7
2.1
2.1
2.0
2.3
2.3
2.2
2.7
2.5
2.5
2.9
2.8
2.8
3.1
3.0
2.9
3.2
3.2
3.1
3.4
3.2
3.1
3.5
3.2
3.1
3.7
3.2
3.1
3.7
3.2
3.1
2.4
2.3
2.3
2.6
2.6
2.5
3.0
2.8
2.8
3.3
3.2
3.1
3.5
3.3
3.3
3.6
3.6
3.5
3.8
3.6
3.5
4.0
3.6
3.5
4.1
3.6
3.5
4.1
3.6
3.5
2.7
2.6
2.6
2.9
2.8
2.8
3.3
3.2
3.1
3.7
3.5
3.5
3.8
3.7
3.7
4.0
4.0
3.9
4.2
4.0
3.9
4.4
4.0
3.9
4.6
4.0
3.9
4.6
4.0
3.9
3.0
2.9
2.9
3.3
3.2
3.2
3.7
3.6
3.5
4.1
4.0
3.9
4.3
4.2
4.1
4.5
4.5
4.4
4.8
4.5
4.4
5.0
4.5
4.4
5.2
4.5
4.4
5.2
4.5
4.4
kcal/h=kW x 860 , BTU/h = kW x 3,412
INDOOR UNITS
All Indoor units
Model
Outdoor
size
air temp.
15°C D.B.
(Rated kW)
°C W.B.
SHC
-15.0
3.5
-10.0
3.8
-5.0
4.3
0.0
4.7
2.5
5.0
40
(5.0)
6.0
5.1
7.5
5.4
10.0
5.7
12.5
5.9
15.5
6.2
-15.0
3.9
-10.0
4.2
-5.0
4.8
0.0
5.3
45
2.5
5.5
(5.6)
6.0
5.7
7.5
6.0
10.0
6.3
12.5
6.6
15.5
6.9
-15.0
4.4
-10.0
4.7
-5.0
5.4
0.0
5.9
2.5
6.2
50
(6.3)
6.0
6.4
7.5
6.8
10.0
7.1
12.5
7.4
15.5
7.7
-15.0
4.9
-10.0
5.3
-5.0
6.0
0.0
6.6
56
2.5
6.9
(7.0)
6.0
7.1
7.5
7.6
10.0
7.9
12.5
8.3
15.5
8.6
-15.0
5.6
-10.0
6.0
-5.0
6.8
0.0
7.5
2.5
7.9
63
(8.0)
6.0
8.2
7.5
8.6
10.0
9.0
12.5
9.4
15.5
9.8
-15.0
6.3
-10.0
6.8
-5.0
7.7
0.0
8.5
71
2.5
8.9
(9.0)
6.0
9.2
7.5
9.7
10.0
10.2
12.5
10.6
15.5
11.1
-15.0
7.0
-10.0
7.5
-5.0
8.5
0.0
9.4
2.5
9.9
80
(10.0)
6.0
10.2
7.5
10.8
10.0
11.3
12.5
11.8
15.5
12.3
C7-R Rev.
SHC:Sensible Heat Capacity(kW)
Indoor air temp.
20°C D.B.
25°C D.B.
27°C D.B.
SHC
SHC
SHC
3.4
3.3
3.2
3.7
3.6
3.5
4.2
4.0
3.9
4.6
4.4
4.4
4.8
4.7
4.6
5.0
5.0
4.9
5.3
5.0
4.9
5.5
5.0
4.9
5.8
5.0
4.9
5.8
5.0
4.9
3.8
3.6
3.6
4.1
4.0
3.9
4.6
4.4
4.4
5.2
4.9
4.9
5.4
5.2
5.2
5.6
5.5
5.4
5.9
5.5
5.4
6.2
5.5
5.4
6.4
5.5
5.4
6.4
5.5
5.4
4.2
4.1
4.0
4.6
4.5
4.4
5.2
5.0
4.9
5.8
5.5
5.5
6.0
5.9
5.8
6.3
6.2
6.1
6.7
6.2
6.1
6.9
6.2
6.1
7.2
6.2
6.1
7.2
6.2
6.1
4.7
4.6
4.5
5.1
5.0
4.9
5.8
5.5
5.5
6.4
6.2
6.1
6.7
6.5
6.4
7.0
6.9
6.8
7.4
6.9
6.8
7.7
6.9
6.8
8.1
6.9
6.8
8.1
6.9
6.8
5.4
5.2
5.1
5.8
5.7
5.6
6.6
6.3
6.2
7.4
7.0
7.0
7.7
7.4
7.4
8.0
7.9
7.8
8.5
7.9
7.8
8.8
7.9
7.8
9.2
7.9
7.8
9.2
7.9
7.8
6.0
5.9
5.8
6.6
6.4
6.3
7.5
7.1
7.0
8.3
7.9
7.8
8.6
8.4
8.3
9.0
8.9
8.7
9.5
8.9
8.7
9.9
8.9
8.7
10.4
8.9
8.7
10.4
8.9
8.7
6.7
6.5
6.4
7.3
7.1
7.0
8.3
7.9
7.8
9.2
8.8
8.7
9.6
9.3
9.2
10.0
9.9
9.7
10.6
9.9
9.7
11.0
9.9
9.7
11.5
9.9
9.7
11.5
9.9
9.7
kcal/h=kW x 860 , BTU/h = kW x 3,412