4. ELECTRICAL WIRING DIAGRAMS

4. ELECTRICAL WIRING DIAGRAMS
PLFY-P32, 40, 50, 63, 80, 100, 125VBM-E-S
[LEGEND]
SYMBOL
NAME
I. B
INDOOR CONTROLLER BOARD
CN27
CONNECTOR
DAMPER
REMOTE SWITCH
CN32
CENTRALLY CONTROL
CN51
CN52
REMOTE INDICATION
FUSE
FUSE (T6.3AL250V)
POWER SUPPLY (I. B)
LED1
LED2
POWER SUPPLY (I. B)
SW2
SWITCH
CAPACITY CODE
SW3
MODE SELECTION
SW4
MODEL SELECTION
SWE
DRAIN PUMP (TEST MODE)
X1
AUX. RELAY
DRAIN PUMP
A.B
GRILLE
ON
MV
MV
MV
MV
OFF
1 2 3 4 5 6 7 8 910
M
M
M
M
SW12
10ths DIGIT 1s DIGIT
5
5
5
5
20
18
16
14
12
10
8
6
4
19
17
15
13
11
9
7
5
3
VANE CNV
(WHT)
I-SEE SENSOR MOTOR
CN6Y
1
(RED)
6
MA REMOCON
CN3A
(BLU)
1
3
I-SEE SENSOR
CN4Y
(WHT)
1
4
LEV
CN60
(WHT)
1
6
CN52
CN51
(GRN)
(WHT)
1
5
1
6
4
5
M
I-SEE
SENSOR
MT
M
I-SEE SENSOR CORNER PANEL
(OPTIONAL PART)
LEV
NOTES:
1. When servicing the outdoor unit, always follow the wiring diagram of outdoor unit.
2. In case of using MA-Remote controller, please connect to TB15.
(Remote controller wire is non-polar.)
3. In case of using M-NET, please connect to TB5. (Transmission line is non-polar.)
4. Symbol [S] of TB5 indicates shield wire connection.
5. Symbols used in wiring diagram above are,
6. The settings of the SW2 dip switches differ in capacity. For details, refer to fig< 1>.
LED on indoor board for service
Mark
Meaning
LED1
Main power supply
Power supply for
LED2
MA-Remote controller
SYMBOL
DP
DRAIN PUMP
FS
DRAIN FLOAT SWITCH
LEV
LINEAR EXPANSION VALVE
MF
FAN MOTOR
MV
VANE MOTOR
TB2
TERMINAL
TB5
BLOCK
TB15
THERMISTOR
TH21
TH22
TH23
< 1>
The black square (■) indicates a switch position.
4
(RED)
ADDRESS
CN43
SWA
SWB
1
8
SW1
3
2
2
3
1
4
(RED)
ADDRESS
SW14
SW11
CN82
SWC
2
1
BRANCH
No.
1
8
4
CN32
J42 J41
(WHT)
2
1
3
1
8
1
Pair No.
ADDRESS
1
ADDRESS
CN81
CN42
(RED)
(RED)
LED2
WIRELESS
CN90
(WHT)
1
9
LIQUID/GAS
CN41
(WHT)
1
5
1
4
9
TB15
ORN
TO MA-REMOTE
BZ
1
CNB
ORN
CONTROLLER
2
DC8.7-13V
SW1
LED2
SW2
LED1
RU
TH22
W.B
: terminal block,
Function
Main Power supply (Indoor unit:220-240V)
power on
Lamp is lit.
Power supply for MA-Remote controller
on
Lamp is lit.
INDOOR UNITS
NAME
POWER SUPPLY
TRANSMISSION
MA-REMOTE CONTROLLER
ROOM TEMP. DETECTION
(0°C / 15kΩ, 25°C / 5.4kΩ)
PIPE TEMP. DETECTION / LIQUID
(0°C / 15kΩ, 25°C / 5.4kΩ)
PIPE TEMP. DETECTION / GAS
(0°C / 15kΩ, 25°C / 5.4kΩ)
MODELS
SW2
MODELS
SW2
ON
ON
P32
P80
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
P40
P100
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
ON
P50
P125
OFF
OFF
1 2 3 4 5 6
1 2 3 4 5 6
ON
P63
OFF
1 2 3 4 5 6
See fig: 1
SW3
SW4
SW2
ON
ON
OFF
OFF
4
1 2 3 4 5 6 7 8 910
1 2 3 4 5
1 2 3 4 5 6
SWE
DC311~339V
OFF
ON
RECTIFICATION
3
CN25
1
3
(WHT)
AUTO GRILLE
1
2
CN3G
(BLK)
LED1
INTAKE
FAN
FLOAT SW
CN27
CN20
CNMF
CN44
CN4F
(RED)
(WHT)
(RED)
(WHT)
(WHT)
4
1
2
1
2
7
1
4
MS
MF
Be sure to turn off the power source
and then disconnect fan motor connector.
TH23
FS
TH21
(Failure to do so will cause trouble in fan motor.)
: connecter.
SYMBOL
NAME
ADDRESS BOARD
A. B
SWA
SWITCH
CEILING HEIGHT SELECTOR
SWB
DISCHARGE OUTLET NUMBER
SELECTOR
SWC
OPTION SELECTOR
SW1
MODE SELECTION
SW11
ADDRESS SETTING 1s DIGIT
SW12
ADDRESS SETTING 10ths DIGIT
SW14
BRANCH NO.
OPTION PART
W.B
PCB FOR WIRELESS REMOTE CONTROLLER
BZ
BUZZER
LED1
LED (OPERATION INDICATION : GREEN)
LED2
LED (PREPARATION FOR HEATING : ORANGE)
RU
RECEVING UNIT
SW1
EMERGENCY OPERATION (HEAT / DOWN)
SW2
EMERGENCY OPERATION (COOL / UP)
TB5
TO OUTDOOR UNIT
BLU
M1
Refrigerant Distributor
BLU
REMOTE CONTROLLER
M2
DC24-30V
S
(SHIELD)
RED
BLU
GRN/YLW
1 3 5
CND
2 1
(BLK)
M-NET
CN2M
(BLU)
FUSE
+
AUTO GRILLE POWER
X1
CNAC
(WHT)
D.U.M
4
3
1
3
1
1
CNP
(BLU)
3
M
1~
3~
DP
3
1
CN3G
AUTOMATIC FILTER ELEVATION PANEL
(OPTIONAL PART)
C7-R Rev.
POWER SUPPLY
~/N 220-240V 50Hz
220V 60Hz
BREAKER
(16A)
FUSE(16A)
TB2
PULL BOX
L
N
TO NEXT
INDOOR UNIT
I.B
U.B
5 3
1
CN3A
1 - 82