Cooling Capacity With Pumy-P200-250Ykmc-C - Mitsubishi Electric CITY MULTI PEFY-P22VMS-E-S Data Book

Table of Contents

Advertisement

3. Cooling [Ceiling cassette (1-way flow type)]

3-2. Cooling capacity with PUMY-P200-250YKMC-C

PMFY-P-VBM-EC
Model
Outdoor
size
air temp.
21.5°C D.B.
(Rated kW)
15°C W.B.
°C D.B.
CA
20.0
2.1
22.5
2.1
25.0
2.0
27.5
2.0
30.0
2.0
20
32.5
1.9
(2.2)
35.0
1.8
37.5
1.8
40.0
1.8
43.0
1.7
46.0
1.6
20.0
2.7
22.5
2.6
25.0
2.6
27.5
2.5
30.0
2.5
25
32.5
2.4
(2.8)
35.0
2.4
37.5
2.3
40.0
2.2
43.0
2.1
46.0
2.0
20.0
3.4
22.5
3.4
25.0
3.3
27.5
3.3
30.0
3.2
32
32.5
3.1
(3.6)
35.0
3.0
37.5
3.0
40.0
2.9
43.0
2.7
46.0
2.6
20.0
4.3
22.5
4.2
25.0
4.1
27.5
4.1
30.0
4.0
40
32.5
3.9
(4.5)
35.0
3.8
37.5
3.7
40.0
3.6
43.0
3.4
46.0
3.3
23°C D.B.
25°C D.B.
16°C W.B.
18°C W.B.
SHC
CA
SHC
CA
1.8
2.2
1.9
2.4
1.8
2.2
1.9
2.3
1.8
2.1
1.9
2.3
1.8
2.1
1.8
2.2
1.8
2.0
1.8
2.2
1.7
2.0
1.8
2.2
1.7
1.9
1.8
2.1
1.7
1.9
1.8
2.1
1.7
1.8
1.7
2.0
1.6
1.8
1.7
1.9
1.6
1.7
1.7
1.8
2.2
2.8
2.3
3.0
2.2
2.7
2.3
2.9
2.2
2.7
2.3
2.9
2.2
2.6
2.3
2.9
2.1
2.6
2.2
2.8
2.1
2.5
2.2
2.7
2.1
2.5
2.2
2.7
2.1
2.4
2.2
2.6
2.0
2.3
2.1
2.5
2.0
2.2
2.1
2.5
1.9
2.1
2.0
2.4
2.6
3.6
2.7
3.9
2.5
3.5
2.6
3.8
2.5
3.5
2.6
3.7
2.5
3.4
2.6
3.7
2.5
3.3
2.5
3.6
2.4
3.2
2.5
3.5
2.4
3.2
2.5
3.5
2.3
3.1
2.4
3.4
2.3
3.0
2.4
3.3
2.2
2.9
2.3
3.2
2.2
2.7
2.3
3.0
3.1
4.5
3.3
4.8
3.1
4.4
3.2
4.7
3.1
4.3
3.2
4.7
3.1
4.2
3.1
4.6
3.0
4.1
3.1
4.5
3.0
4.1
3.1
4.4
2.9
4.0
3.0
4.3
2.9
3.9
3.0
4.2
2.8
3.7
2.9
4.1
2.7
3.6
2.8
4.0
2.7
3.4
2.8
3.8
INDOOR UNITS
Indoor air temp.
27°C D.B.
28°C D.B.
19°C W.B.
20°C W.B.
SHC
CA
SHC
CA
1.9
2.4
2.0
2.5
1.9
2.4
2.0
2.5
1.9
2.4
2.0
2.5
1.8
2.3
2.0
2.4
1.8
2.3
2.0
2.4
1.8
2.3
2.0
2.4
1.8
2.2
1.9
2.3
1.8
2.2
1.9
2.2
1.7
2.1
1.9
2.2
1.7
2.0
1.9
2.1
1.7
1.9
1.8
2.0
2.3
3.1
2.5
3.2
2.3
3.1
2.5
3.2
2.3
3.0
2.4
3.1
2.3
3.0
2.4
3.1
2.2
2.9
2.4
3.1
2.2
2.9
2.4
3.0
2.2
2.8
2.4
2.9
2.2
2.7
2.3
2.9
2.1
2.7
2.3
2.8
2.1
2.6
2.3
2.7
2.0
2.5
2.2
2.5
2.7
4.0
2.8
4.1
2.6
3.9
2.8
4.1
2.6
3.9
2.8
4.0
2.6
3.8
2.8
4.0
2.6
3.8
2.7
3.9
2.5
3.7
2.7
3.9
2.5
3.6
2.7
3.8
2.5
3.5
2.6
3.7
2.4
3.4
2.6
3.6
2.4
3.3
2.5
3.5
2.3
3.2
2.5
3.3
3.3
5.0
3.5
5.1
3.2
4.9
3.4
5.1
3.2
4.9
3.4
5.0
3.2
4.8
3.4
5.0
3.1
4.7
3.3
4.9
3.1
4.6
3.3
4.8
3.0
4.5
3.2
4.7
3.0
4.4
3.2
4.6
2.9
4.3
3.1
4.5
2.9
4.1
3.1
4.3
2.8
4.0
3.0
4.1
C7-R Rev.
CA:Capacity(kW) , SHC:Sensible Heat Capacity(kW)
30°C D.B.
32°C D.B.
22°C W.B.
24°C W.B.
SHC
CA
SHC
CA
2.0
2.7
2.0
2.8
2.0
2.6
2.0
2.7
2.0
2.6
2.0
2.7
2.0
2.6
2.0
2.6
2.0
2.5
1.9
2.6
2.0
2.5
1.9
2.6
1.9
2.4
1.9
2.5
1.9
2.4
1.9
2.5
1.9
2.4
1.9
2.4
1.9
2.3
1.9
2.4
1.8
2.2
1.8
2.3
2.5
3.4
2.4
3.5
2.5
3.4
2.4
3.4
2.4
3.3
2.4
3.4
2.4
3.3
2.4
3.4
2.4
3.2
2.4
3.3
2.4
3.2
2.4
3.3
2.4
3.1
2.3
3.2
2.3
3.1
2.3
3.2
2.3
3.0
2.3
3.1
2.3
2.9
2.3
3.0
2.2
2.8
2.2
2.9
2.8
4.4
2.8
4.5
2.8
4.3
2.8
4.4
2.8
4.3
2.7
4.4
2.8
4.2
2.7
4.3
2.7
4.1
2.7
4.3
2.7
4.1
2.7
4.2
2.7
4.0
2.6
4.1
2.6
3.9
2.6
4.1
2.6
3.9
2.6
4.0
2.5
3.7
2.5
3.9
2.5
3.6
2.5
3.8
3.4
5.4
3.4
5.6
3.4
5.4
3.4
5.5
3.4
5.4
3.4
5.5
3.4
5.3
3.3
5.4
3.3
5.2
3.3
5.4
3.3
5.1
3.2
5.3
3.3
5.0
3.2
5.2
3.2
4.9
3.2
5.1
3.1
4.8
3.1
5.0
3.1
4.7
3.1
4.9
3.0
4.5
3.0
4.7
kcal/h=kW x 860 , BTU/h = kW x 3,412
SHC
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.9
1.8
1.8
1.8
2.4
2.3
2.3
2.3
2.3
2.3
2.3
2.3
2.2
2.2
2.2
2.7
2.7
2.6
2.6
2.6
2.6
2.6
2.5
2.5
2.5
2.4
3.3
3.2
3.2
3.2
3.2
3.2
3.1
3.1
3.1
3.0
3.0
1 - 155