Beckhoff CU8110-0060 Manual page 41

Table of Contents

Advertisement

Status in-
Beckhoff BAPI
formation
v1
FirmwareR
X
ev
SerialNum
X
ber
BatteryLife
X
Percent
BatteryLife
X
Time
eBatterySt
BatteryOk
atus
eCommSta
X
tus
ePowerSta
X
tus
nPowerFail
X
Cnt
dwCharge
No Battery (bit 7
Flags
set) from UPS
firmware
>=33.12-0 if no
battery
isconnected.
Service Interval
Notify (bit 10
set). The
configured
battery change
interval service
has expired
CU8110-0060
Beckhoff
Beckhoff 24V
P24Vxxxx UPS
UPS on the
CP903x card
X
X
X
None
X
None
X
None
BatteryUnknow
BatteryUnknow
nStatus if no
nStatus if no
battery exists;
battery exists.
from UPS
software version
BatteryOk
>= 2.0.0.6 and
UPS firmware >=
25.1.I
BatteryOk
X
X
X
X
X
X
No Battery (bit 7
High (bit 0 set) if
set) from UPS
battery is fully
software version
charged.
>= 2.0.0.6 and
firmware >=
Charging (bit 3
25.1.I. The
set)
existence of the
battery is
checked every
No Battery (bit 7
minute.
set) if no battery
was found.
UPS Fan Error
(bit 8 set) from
UPS software
version >=
2.0.0.7 and
firmware >=
40.1.I. The UPS
fan status is
checked each
minute.
Requires a
newer (second)
hardware
revision!
Version: 1.0
CX2100-09x4
APC
APC
Back-
Smart-
UPS
UPS 420
Pro
280
X
X
X
X
X
X
X
X
BatteryUnknownS
X
tatus when no
battery is present
(applicable only for
the model with
"Smart Battery"
and not with
capacitors)
BatteryOk
X
X
X
X
X
*X
No Battery (bit 7
None
set). No
communication to
the battery
(applicable only for
the model with
"Smart Battery"
and not with
capacitors).
Over Temperature
(bit 9 set) was
detected and the
charging of the
battery was
interrupted.
Requires a newer
(second)
hardware
revision.
Implemented in the
UPS software
version >=
3.0.0.18.
Service Interval
Notify (bit 10 set).
The configured
Configuration
Description
X
UPS firmware version
information. Empty string
if the UPS does not
support this parameter.
X
Serial number of the UPS.
Empty string if the UPS
does not support this
parameter.
X
Remaining battery life in
percent. The value is
always zero if the UPS
cannot supply this
parameter.
X
Remaining battery life in
minutes. The value is
always zero if the UPS
cannot supply this
parameter.
X
Battery status (type:
E_BatteryStatus).
X
Status of the
communication with the
UPS (type:
E_UpsCommStatus).
X
Status of external power
supply (type:
E_UpsPowerStatus).
*X
Power-fail counter. The
counter is incremented if a
voltage failure is detected
by the UPS service.
None
Battery charge status
flags and special status
information.
41

Advertisement

Table of Contents
loading

Table of Contents