Connection Via Usb; Fig. 13 Example Of A Connection Via Usb With A Cu8110-0060 Ups And A Cx5240 Embedded Pc - Beckhoff CU8110-0060 Manual

Table of Contents

Advertisement

Commissioning
6.3.3

Connection via USB

For devices without UPS-OCT support, communication is provided by the USB interface. Status data can
likewise be retrieved for diagnostic purposes or the UPS configured when communicating via USB.
Fig. 13: Example of a connection via USB with a CU8110-0060 UPS and a CX5240 Embedded PC.
The USB interface conforms to the USB 2.0 standard. The cable length is limited to 5 m.
24
L1
L2
L3
N
PE
- System
Supply
230V
24V
Shielding
Grounding busbar
Version: 1.0
CU8110-0 0
06
Uin
Uout
DIAG
X101
Uin
P SHDN
OV
UPS EN
PE
NC
U1out
NC
OV
P FAIL
PE
OV
U2out
UPS RDY
OV
OV
PE
PE
X102
CU8110-0060